WhatsBusted
3D model of an ac condenser
Symptom

Outdoor AC unit won't turn off

The thermostat is off but the outdoor unit keeps running. Shut it down at the disconnect. A stuck contactor is the usual reason.

Check these first

Five-minute checks, no tools

  • Shut it off at the disconnect

    Pull the disconnect beside the outdoor unit or turn off the AC breaker. Do not let it keep running.

  • Thermostat really off?

    Check that the thermostat is set to Off, not just set higher, and that it is not on a schedule calling for cooling.

  • Check for ice

    Look at the lines at the outdoor unit and the indoor coil if you can see it. If there is ice, leave the AC off and set the fan to On to thaw it.

Likely causes

Ranked by how often they are the problem

  1. 1

    Contactor

    DIY fix

    The contacts have welded shut or the plunger is stuck in, so the outdoor unit stays on with the thermostat off.

    Fix the contactor30 min–1 hr$20–$100
  2. 2

    Thermostat or control wiring

    Call a pro

    The thermostat or a shorted control wire keeps sending the cooling call. Call a pro if a new contactor does not fix it.

  3. 3

    System can't keep up

    Call a pro

    The thermostat is still calling because the house never reaches the set temperature. See AC not cooling.

What's happening

What your AC condenser is doing

The contactor is supposed to open and cut power to the compressor and fan when the thermostat's call ends. If its contacts weld together, the outdoor unit keeps running no matter what the thermostat says.

Running nonstop like this can freeze the indoor coil.

If the outdoor unit runs nonstop while the thermostat is calling, that is a different problem: the system cannot keep up. See AC not cooling.

Know your limits

When to call a pro

Stop and call a pro if

  • A new contactor goes in and the unit still will not shut off.
  • The indoor coil or the lines are covered in ice.
  • You see burned or melted wires at the contactor.

FAQ

Common questions

Is it bad if my outdoor AC unit runs with the thermostat off?

Yes. Turn it off at the disconnect or the breaker. A stuck contactor keeps the unit running, which wastes power and can freeze the indoor coil.

Can I tap the contactor to free it?

No. It carries line voltage. Turn the power off, then replace the contactor. A contactor that sticks once will do it again.

Is a stuck contactor expensive to fix?

No. A contactor is an inexpensive part, and a pro's replacement typically costs a few hundred dollars at most.

Related

Keep going

Get the next fix before it breaks

A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.