Outdoor AC unit won't turn on
The thermostat is calling, maybe the indoor fan is even blowing, but the outdoor unit is silent. Start with the switches: the disconnect and the breaker.
Check these first
Five-minute checks, no tools
Thermostat on Cool, set low enough
Set it to Cool and a few degrees below room temperature. Replace its batteries if the display is blank or dim.
AC breaker
Find the AC breaker in the main panel. If it has tripped, reset it once. If it trips again, leave it off and call a pro.
Outdoor disconnect
Check the disconnect box on the wall beside the unit. Make sure its handle is in and on. It is easy to leave it pulled after a cleaning or service.
Filter and indoor unit
Make sure the indoor unit is running and the filter is clean.
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Contactor
Power is on and the thermostat is calling, but the outdoor unit stays silent. Burned contacts or an open coil.
Fix the contactor30 min–1 hr$20–$100 - 2DIY fix
Dual run capacitor
A faint hum but no fan or compressor. Listen closely: a hum means power is getting there.
Fix the capacitor20–45 min$10–$60 - 3Call a pro
Thermostat or low-voltage wiring
The 24 V call never reaches the outdoor unit. A thermostat problem or a broken control wire has cut the call. Call a pro if the thermostat checks out.
What's happening
What your AC condenser is doing
When the thermostat calls for cooling, it sends 24 V to the outdoor unit's contactor. The contactor pulls in and sends line voltage to the compressor and fan.
If the outdoor unit is completely silent, either no power is reaching it (a tripped breaker or a pulled disconnect) or the call is not getting through.
If power and the thermostat are fine, a contactor with burned contacts or a dead coil is the usual part.
Know your limits
When to call a pro
Stop and call a pro if
- The AC breaker trips again right after a reset.
- The thermostat, breaker and disconnect are fine, the contactor is new, and the outdoor unit still never starts.
- You see burned or melted wires, or smell burning.
FAQ
Common questions
Why won't my outdoor AC unit turn on but the inside fan runs?
Check the outdoor disconnect and the AC breaker first. If both are on, the contactor is a common culprit: the thermostat's signal is not closing it.
How many times can I reset the AC breaker?
Once. If it trips again right away, something is drawing too much current. Leave it off and call a technician.
Where is the AC disconnect?
In a small metal box on the outside wall near the outdoor unit. Depending on the type, you pull out a handle or flip a switch to turn it off. Never open the box's inner panel: its supply side stays live.
Related
Keep going
- SymptomAC humming but not startingWhen the outdoor unit hums but the fan and compressor do not start, the dual run capacitor is the most likely part. A contactor that buzzes or chatters can cause it too. If both test good, a seized compressor is the pro-only possibility.Open guide
- SymptomAC running but not coolingIf the indoor fan blows but the air is warm, look at the outdoor unit. A fan that will not spin, a hum with nothing turning, or a coil packed with debris all stop the cooling. Ice on the lines points to a dirty filter first, and to low refrigerant if the filter is clean.Open guide
- AC condenser partContactorThe contactor is the heavy switch that turns the outdoor unit on when the thermostat calls for cooling. Burned contacts or a dead coil leave the unit silent. Welded contacts keep it running nonstop. It swaps out with a few wires and two screws.Open guide
- AC condenser partDual run capacitorThe dual run capacitor helps the compressor and the outdoor fan start and run. When it weakens, the unit hums without starting, the fan will not spin, or cooling fades. It is a few wires and one strap, but it must be discharged before you touch it.Open guide
Get the next fix before it breaks
A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.