WhatsBusted
3D model of a dual run capacitor
Most common failureAlso called AC capacitor, run capacitor

AC capacitor test and replacement

A common outdoor-unit failure, and one of the cheapest parts. It stores a dangerous charge, though, so the safety steps here are not optional.

Difficulty
Moderate
Time
20–45 min
Typical part cost
$10–$60Pro: $80–$400

The swap itself is easy: a strap and three terminals. The rating is for the high-voltage safety: proving the power is off and discharging the capacitor before you touch it.

What it does

What the capacitor does

A dual run capacitor is two capacitors in one metal can. The larger section serves the compressor, the smaller one the outdoor fan motor. Its three terminals are marked C (common), HERM (the compressor) and FAN.

The label lists both ratings in microfarads, for example 45/5 µF, plus a voltage rating such as 370 or 440 VAC and a tolerance.

Why it fails

Capacitors lose capacity with age and heat. Most last many years, but a weak one can no longer give the motors the push they need.

A failing capacitor often bulges on top.

Symptoms

Signs of a bad capacitor

  • Humming, but nothing starts

    You hear a hum from the outdoor unit but the fan does not turn and the compressor does not start.

    Full diagnosis
  • Fan will not spin, or needs a push

    The compressor hums but the fan sits still. Do not try to push-start it: a fan that only starts with a nudge is a sign of a weak capacitor.

    Full diagnosis
  • Warm air indoors

    The indoor blower runs but the air is not cold, and the outdoor unit hums faintly or keeps stopping.

    Full diagnosis
  • Bulged top or oily leak

    With the power off and the panel open, the capacitor's top is domed instead of flat.

How to test it

Test the capacitor before you buy

1. Look first, from outsideNo meter needed
  1. Listen at the outdoor unit while the thermostat calls for cooling. Note whether the fan turns and whether the compressor hums or runs.
  2. Do not reach into the unit, and keep sticks and fingers out of the fan.
Good
Fan turning and compressor running steadily. The capacitor is probably fine.
Bad
A hum with nothing turning, or the fan still while the compressor hums. Turn the thermostat off and go through the safety steps before testing.
2. Capacitance testMeter on µF (capacitance)
  1. With the power off, tested and the capacitor discharged (steps below), photograph and remove the wires from its terminals.
  2. Probe C and HERM and read the value. Then probe C and FAN. Never probe HERM to FAN.
  3. Compare each reading with the rating printed on the label.

A good capacitor typically reads

Within about ±6% of each rating on its label

Typical range. Check your part label or manual for the exact spec.

Good
Both sections read within the tolerance on the label. The capacitor is fine; look at the contactor or the fan motor next.
Bad
Either section reads low or near zero, or the can is bulged or leaking. Replace it.

Safety first

Before you touch anything

  1. 1

    Thermostat off, disconnect out, breaker off

    Set the thermostat to off. Pull the disconnect handle or switch it off at the box beside the unit, then turn off the AC breaker in the main panel. There may be more than one disconnect.

  2. 2

    Prove it is dead

    Before you touch any wire, test at the unit with a voltage tester, checked first on a live outlet. A disconnect can fail and leave a leg live. The supply side of the disconnect stays live no matter what, so never work inside the disconnect box.

  3. 3

    Discharge the capacitor

    A capacitor holds its charge after the power is off, and its internal bleed resistor may have failed. Bleed it with a resistor discharge tool across C to HERM and C to FAN, then confirm 0 V on your meter. Never short the terminals with a screwdriver.

  4. 4

    Glasses on

    Wear safety glasses. A failing capacitor can spark as it discharges.

Tools you'll need

Grab these first

Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works

See the full repair tool kit

Step by step

How to replace the capacitor

  1. 1

    Shut it all off

    Set the thermostat to off. At the outdoor unit, pull the disconnect or switch it off. Then turn off the AC breaker in the main panel.

    Put tape over the breaker and tell the household so no one turns it back on.

  2. 2

    Open the electrical panel

    Remove the screws holding the electrical access panel, usually on the corner of the cabinet near where the refrigerant lines enter, and set it aside.

  3. 3

    Test for voltage

    Hold your voltage tester to the wires coming into the contactor. It should stay silent. If it beeps or lights, stop: the power is still on somewhere.

  4. 4

    Discharge the capacitor

    Clip the discharge tool's leads across C and HERM, then across C and FAN, holding only the insulated handles. Then set your meter to AC volts and confirm 0 V on both pairs.

    Careful. Do not use a screwdriver to short the terminals. A charged capacitor can arc, burn and damage itself.

  5. 5

    Photograph and label the wires

    Take a clear photo of the capacitor's terminals showing which wire goes to C, HERM and FAN. Wrap a bit of tape on each wire marked with its terminal.

  6. 6

    Remove the old capacitor

    Pull each wire straight off its terminal with pliers. Loosen the strap or bracket and lift the capacitor out.

    Read its label: both µF ratings and the voltage. You need those to buy the replacement.

  7. 7

    Match the new capacitor

    The new capacitor must have the same two µF ratings, and a voltage rating the same or higher. A 440 V capacitor can replace a 370 V one, but not the other way around.

  8. Buy the part

    Dual run capacitor

    Opens Amazon in a new tab. Where’s my model number?

    What to look for

    • The two µF ratings on the old capacitor's label, for example 45/5. Both must match.
    • A voltage rating the same as or higher than the old one, usually 370 or 440 VAC.
    • A round or oval can that fits the unit's strap. Size matters less than the ratings.

    Generic capacitors are fine as long as both µF ratings and the voltage rating match. You do not need the brand-name part.

  9. 8

    Install and wire it

    Set the new capacitor in the strap and tighten it. Push each wire firmly onto the matching terminal: C, HERM and FAN, exactly as in your photo.

    Tug each wire gently to make sure it is seated.

  10. 9

    Close up and power up

    Refit the access panel. Turn the breaker on, reinsert the disconnect, and set the thermostat to cool.

    Within a few minutes (many systems wait a few minutes before restarting), the fan should spin and the compressor should hum steadily.

Buy the part

Get the right replacement

Buy the part

Dual run capacitor

Opens Amazon in a new tab. Where’s my model number?

What to look for

  • The two µF ratings on the old capacitor's label, for example 45/5. Both must match.
  • A voltage rating the same as or higher than the old one, usually 370 or 440 VAC.
  • A round or oval can that fits the unit's strap. Size matters less than the ratings.

Generic capacitors are fine as long as both µF ratings and the voltage rating match. You do not need the brand-name part.

Know your limits

When to call a pro

Stop and call a pro if

  • You are not comfortable proving the power is off or discharging a capacitor.
  • A new capacitor goes in and the compressor still hums without starting, or the breaker trips. The compressor may be seized.
  • Wires or terminals in the unit are burned, melted or loose.
  • The capacitor fails again within weeks. Something else is stressing it.

FAQ

Dual run capacitor questions

How do I know what capacitor to buy?

Read the label on the old one: two µF numbers and a voltage. Match both µF values exactly and use the same voltage or higher.

Is it safe for a homeowner to replace an AC capacitor?

Only if you follow every safety step. The power must be off and proven off, and the capacitor discharged with a proper tool and checked at 0 V. If any step makes you uneasy, call a pro: this is a short, inexpensive service call.

Can I use a higher-voltage capacitor?

Yes. A higher voltage rating is fine, for example 440 V in place of 370 V. The microfarad ratings must match.

My capacitor is not bulged. Can it still be bad?

Yes. Many weak capacitors look normal. The meter test tells you for sure.