AC running but not cooling the house
Air blows but it is not cold. Before you call anyone, check the thermostat, the filter and the outdoor unit. Those three solve a lot of no-cool calls.
Check these first
Five-minute checks, no tools
Thermostat on Cool
Make sure it is set to Cool, set a few degrees below room temperature, and has fresh batteries if it uses them.
Change the filter
A clogged filter can freeze the indoor coil and leave the AC running all day without cooling. Replace it if it is grey or dusty.
Breaker and disconnect on
Check the AC breaker in the main panel and the disconnect beside the outdoor unit. Reset a tripped breaker once. If it trips again, leave it off and call a pro.
Look at the outdoor unit
Is the fan on top spinning? Is the coil clear of leaves, grass and dirt, with space all around? Do not reach inside.
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Dual run capacitor
The outdoor unit hums faintly, or the fan or compressor will not start. A common outdoor-unit failure.
Fix the capacitor20–45 min$10–$60 - 2DIY fix
Dirty condenser coil
Everything runs, but the fins are matted with debris or plants crowd the unit, so heat cannot get out.
Fix the condenser coil20–45 min$0 - 3DIY fix
Condenser fan motor
The compressor runs but the fan on top does not turn, even with a good capacitor.
Fix the fan motor45 min–1.5 hr$60–$400 - 4DIY fix
Contactor
The indoor fan blows but the outdoor unit never starts at all.
Fix the contactor30 min–1 hr$20–$100 - 5Call a pro
Refrigerant leak
Both units run and the filter and coil are clean, but the air is warm, and ice may form on the lines. Call a pro.
- 6Call a pro
Compressor
The fan runs but the compressor never starts, even with a good capacitor and contactor. Call a pro.
What's happening
What your AC condenser is doing
Cooling needs both halves working: the indoor blower moving air over the cold indoor coil, and the outdoor unit's compressor and fan moving that heat outside.
If the outdoor unit hums but nothing turns, or its fan sits still while the compressor runs, the heat cannot leave. A weak capacitor is a common reason.
If both units run and the air is still warm, look at airflow: a clogged filter or a dirty outdoor coil. Ice on the lines or the indoor coil can come from a dirty filter, a dirty coil, blocked vents or low refrigerant.
Know your limits
When to call a pro
Stop and call a pro if
- There is ice on the lines or indoor coil with a clean filter.
- The breaker trips again right after a reset.
- The outdoor unit hums and will not start after the capacitor tests good or has been replaced.
- You see oily spots on the lines or coil, or hear a hiss.
FAQ
Common questions
Why is my AC running but blowing warm air?
Check the thermostat and the filter first. Then look at the outdoor unit: if it hums without starting or its fan is still, the capacitor is the most likely part. If both units run normally, a dirty coil or low refrigerant is likely.
My AC lines are frozen. What do I do?
Turn the system off at the thermostat and set the fan to On to thaw the coil. Replace the filter. If it freezes again with a clean filter, call a technician.
How long should it take to cool the house?
On a very hot day a central AC may run for long stretches and only lower the temperature slowly. If it runs all day and the house never cools, or the vents blow warm air, something is wrong.
Related
Keep going
- SymptomAC humming but not startingWhen the outdoor unit hums but the fan and compressor do not start, the dual run capacitor is the most likely part. A contactor that buzzes or chatters can cause it too. If both test good, a seized compressor is the pro-only possibility.Open guide
- SymptomAC condenser fan not spinningIf the outdoor fan will not spin, the capacitor is the most likely part, especially if the fan hums or starts with a nudge. If the capacitor is good and the blade is stiff or the motor smells burnt, replace the fan motor.Open guide
- SymptomOutdoor AC unit won't turn onA silent outdoor unit is usually no power or no call. Check the thermostat, the AC breaker and the disconnect beside the unit. If they are fine and the unit still does not start, the contactor is a common culprit.Open guide
- AC condenser partDual run capacitorThe dual run capacitor helps the compressor and the outdoor fan start and run. When it weakens, the unit hums without starting, the fan will not spin, or cooling fades. It is a few wires and one strap, but it must be discharged before you touch it.Open guide
- AC condenser partCondenser coilThe condenser coil wraps the outside of the unit and gives off the heat from your house. When its fins clog with dirt and debris, the AC cools less and runs longer. Manufacturers tell owners to keep it clean with a soft brush and a gentle rinse.Open guide
- AC condenser partCondenser fan motorThe fan motor on top of the outdoor unit spins the blade that pulls air through the coil. When it fails, heat builds up, cooling stops and the compressor overheats. It hangs from the top grille, with a blade, a few bolts and a few wires.Open guide
- AC condenser partContactorThe contactor is the heavy switch that turns the outdoor unit on when the thermostat calls for cooling. Burned contacts or a dead coil leave the unit silent. Welded contacts keep it running nonstop. It swaps out with a few wires and two screws.Open guide
Get the next fix before it breaks
A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.
We send it with Kit. Privacy