WhatsBusted
3D model of a flame sensor
Also called flame rod, flame sensor rod

Furnace flame sensor cleaning and replacement

Good news: this fix usually costs next to nothing. One wire, one screw, a quick polish, and the burners stay lit.

Difficulty
Anyone can do it
Time
10–20 min
Typical part cost
$10–$50Pro: $75–$250

One wire and one screw, in plain sight. The only care needed is with the brittle porcelain.

What it does

What the flame sensor does

The flame sensor is a thin metal rod in a white porcelain insulator, on a small bracket. Its tip sits in the burner flame, usually at the opposite end of the row from the igniter. Its one job is to tell the control board that the burners really lit.

It works because a flame can carry a little electricity. The board puts a voltage on the rod. When the burners are lit, a tiny current flows from the rod, through the flame, to the grounded burner. It is measured in microamps, which are millionths of an amp.

If the board sees that current, it keeps the gas valve open. If it does not see it within a few seconds, it assumes the gas never lit and shuts the valve. That is what stops a furnace from feeding unburned gas into your home.

Why it fails

Over time the rod picks up a thin coating of carbon, soot and oxidation. The coating acts like insulation. The signal gets weaker until the board can no longer see it, even though the burners are lit.

Less often the sensor itself is damaged. The porcelain can crack, the rod can corrode badly, or the wire connector can work loose.

A weak signal can also come from a poor ground. The current returns through the burner and the furnace chassis, so a loose ground connection has much the same effect as a dirty rod.

Symptoms

Signs of a bad flame sensor

  • Lights, then goes out

    The igniter glows and the burners light normally. A few seconds later they shut off again. This is the classic dirty flame sensor.

    Full diagnosis
  • Tries again, then gives up

    The furnace waits, relights, and drops out again. After a few rounds the board locks out and flashes an error code.

    Full diagnosis
  • Works some days, not others

    A lightly coated rod sits right at the edge of what the board can read. The furnace may heat fine for a day, then fail several starts in a row.

    Full diagnosis
  • A dull or crusty rod

    With the power off, look at the rod. Clean metal is bright. A dark, white or sooty coating is what blocks the signal. It does not have to look bad to cause trouble.

  • Blowing cold air

    If the thermostat fan is set to On, the blower keeps running while the burners are out. The vents blow room-temperature air.

    Full diagnosis

How to test it

Test the flame sensor before you buy

Look it overNo meter needed
  1. Power off at the service switch or breaker, and let the burner area cool.
  2. Take off the upper door and find the sensor at the burners. Shine a light on it.
  3. Check the rod, the porcelain and the wire connector.

Many rods have a bend near the tip from the factory. That is fine. What matters is that the tip still sits in the flame.

Good
The porcelain is whole, the rod sits in the flame path, and the connector grips firmly. A dull or sooty coating is normal. Clean it.
Bad
Cracked porcelain, a badly corroded rod, or a rod bent out of the flame path. Replace the sensor. A loose or corroded connector needs fixing too.

Safety first

Before you touch anything

  1. 1

    Kill the power

    Flip the furnace service switch off, or turn off its breaker. The control board light should go dark. Before you pull the sensor wire, check it with a voltage tester. Try the tester on a working outlet first so you know it works.

  2. 2

    Close the gas shutoff

    Turn the handle on the gas line a quarter turn so it sits crosswise to the pipe. You will not open any gas fittings in this job. This is just a second layer of safety.

  3. 3

    Let it cool

    The rod sits right in the flame. If the furnace just tried to run, give it a few minutes before you touch it.

    Wait about 10 min

Tools you'll need

Grab these first

Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works

See the full repair tool kit

Step by step

How to clean or replace the flame sensor

  1. 1

    Shut off the power and the gas

    Flip the service switch on or near the furnace to off. It looks like a light switch. If you cannot find one, turn off the furnace breaker.

    Then turn the gas shutoff handle a quarter turn so it sits crosswise to the pipe.

    Tip. Not sure the power is off? Turn the thermostat up. Nothing should start, and the status light on the control board should stay dark.

  2. 2

    Take off the upper door

    The upper door covers the burner compartment. Most lift up and pull away. Some have two screws along the top edge.

    Set the door somewhere it will not get stepped on.

  3. 3

    Find the flame sensor

    Look at the row of burners. The igniter is usually at one end. The flame sensor is usually at the other end, with its rod reaching into the path of a burner flame.

    It is a single bare metal rod with a white porcelain collar, held on a small bracket by one screw. One wire runs to it. The igniter has two wires and a plastic plug, so the two are easy to tell apart.

    Tip. Take a photo now. It shows how the rod sits in front of the burner, which is how it has to go back.

  4. 4

    Pull the wire off

    Hold the voltage tester to the sensor wire. It should stay quiet. If it beeps or lights, stop and find the right breaker.

    The wire ends in a push-on connector that grips a flat tab on the sensor. Hold the connector, not the wire, and pull it straight off. A gentle wiggle helps if it is tight.

    Look at the connector while it is off. It should be clean and it should grip firmly. A loose or corroded connector can cause the same symptom as a dirty rod.

    Tip. On some furnaces the wire is fixed to the sensor and unplugs a few inches away instead.

  5. 5

    Remove the mounting screw

    One screw holds the sensor bracket, usually a 1/4 in. hex head. Back it out with the nut driver and put it somewhere safe. A new sensor may not come with one.

    Tip. A magnetic nut driver stops the screw from dropping behind the burners.

  6. 6

    Slide the sensor out

    Pull the sensor straight out of its opening. Go gently. The white porcelain is brittle and cracks if it gets knocked.

  7. 7

    Decide: clean it or replace it

    Look it over in good light. A dull, white or sooty coating on the rod is normal. That one gets cleaned in the next step.

    Replace it instead if the porcelain is cracked, the rod is badly corroded or bent out of the flame path, or a cleaning did not fix the problem last time. Sensors are inexpensive.

    Replacing it? Hold the old and new sensors side by side. The bracket, the rod length and the bend should match. Skip the next step and go straight to putting the new one in.

  8. Buy the part

    Flame sensor

    Opens AppliancePartsPros in a new tab. Where’s my model number?

    What to look for

    • Any part number stamped on the bracket. Many sensors have none, so searching by your furnace model number is the surest match.
    • The same bracket shape and screw position, so it mounts in the original hole.
    • The same rod length and the same bend, so the tip sits in the flame exactly where the old one did.
    • The same size of push-on terminal, so the wire connector grips it firmly.

    Sensors vary by model. A universal one is only a fair choice when the bracket lines up with the original screw hole and the rod ends up in the same spot in the flame. If you would have to bend or force anything to make it fit, get the exact part instead.

  9. 8

    Polish the rod

    Hold the sensor by its bracket. Rub the metal rod gently with a fine abrasive pad, fine steel wool or fine emery cloth, working along its length and turning it as you go. Use light pressure. Stop when it is bright all the way around. This takes less than a minute.

    Clean only the metal. Leave the porcelain alone, apart from a gentle wipe. Then wipe the rod with a clean, dry cloth or paper towel to take off the dust and any loose fibers.

    Careful. No sandpaper, files or wire wheels. Rough abrasives scratch the rod, and some sandpapers leave a residue on it. You are taking off a coating, not metal.

  10. 9

    Put the sensor back

    Slide the sensor, cleaned or new, back into its opening the same way the old one came out. Line up the bracket and snug the screw. Firm is enough.

    Check it against your photo. The rod should sit in the path of the burner flame, and it must not touch the burner or any other metal.

  11. 10

    Reconnect the wire

    Push the connector onto the tab until it is fully seated. It should feel snug. Keep the wire clear of the burners.

  12. 11

    Put the door back on

    Refit the upper door. Many furnaces will not run unless the doors are seated, because a door switch cuts power when one is off.

  13. 12

    Turn it back on and watch it stay lit

    Turn the gas shutoff handle back in line with the pipe, then flip the power on. Set the thermostat a few degrees above room temperature.

    Watch through the sight glass or the door louvers. The burners should light and stay lit, well past the point where they used to cut out. Let the furnace run for a few minutes, until the blower comes on.

    Tip. If the furnace was locked out, switching the power off and back on usually clears it.

Buy the part

Get the right replacement

Buy the part

Flame sensor

Opens AppliancePartsPros in a new tab. Where’s my model number?

What to look for

  • Any part number stamped on the bracket. Many sensors have none, so searching by your furnace model number is the surest match.
  • The same bracket shape and screw position, so it mounts in the original hole.
  • The same rod length and the same bend, so the tip sits in the flame exactly where the old one did.
  • The same size of push-on terminal, so the wire connector grips it firmly.

Sensors vary by model. A universal one is only a fair choice when the bracket lines up with the original screw hole and the rod ends up in the same spot in the flame. If you would have to bend or force anything to make it fit, get the exact part instead.

Know your limits

When to call a pro

Stop and call a pro if

  • You smell gas at any point. Do not touch any switches. Leave the house and call your gas utility from outside.
  • Your carbon monoxide alarm goes off. Get everyone outside to fresh air, then call 911 or the fire department from outside.
  • The burners still drop out within seconds with a clean or new sensor. The cause may be a poor ground, the wiring or the control board. A pro can measure the flame signal with a microamp meter to find out.
  • The flames look lazy, yellow or lifted off the burners, or do not reach the sensor. That is a burner or gas problem.
  • The burners light late with a bang or a puff of flame.
  • You see scorch marks, melted wires or flame rolling out around the burners.
  • The rod is coated again within a few weeks. Something is off with the way the furnace is burning.

FAQ

Flame sensor questions

How do I know if it is the flame sensor or the igniter?

Watch a start-up. If the burners light and then go out a few seconds later, suspect the flame sensor. If there is no orange glow and no flame at all, suspect the igniter.

Should I clean the sensor or just replace it?

Clean it first. Most sensors just need the coating polished off, and that costs nothing. Replace it if the porcelain is cracked, the rod is badly corroded, or cleaning does not fix the problem.

How often should I clean the flame sensor?

Have it looked at once a year, ideally before the heating season starts. It takes a few minutes and heads off one of the most common mid-winter breakdowns.

I cleaned the sensor and the furnace still shuts off. Now what?

Check the basics first. The wire should be pushed firmly onto the sensor, the porcelain should not be cracked, and the rod should sit in the flame without touching the burner. If all of that is right, try a new sensor. They are cheap. If a new one does not help either, a pro can measure the flame signal and check the ground.

Then time the shutdown. A flame sensor problem shows up within seconds of the burners lighting. If the burners run for several minutes before they quit, look at airflow and the high limit switch instead.

Is it safe to keep running the furnace with a dirty flame sensor?

A dirty sensor fails safe. It shuts the gas off instead of leaving it on, so the usual result is no heat, not a gas leak. Do not keep resetting the furnace to squeeze out a few minutes of warmth, though. Fix the cause.

And never try to bypass the sensor. It is what shuts the gas off when the burners fail to light.

Related

Keep going