Furnace blowing cold air

Air is moving, so the blower works. The question is why there is no heat behind it. Start with the thermostat. It is the most common answer and it costs nothing.

Check these first

Five-minute checks, no tools

  • Fan set to Auto, not On

    On On, the blower runs nonstop and pushes cool air between heating cycles. Switch it to Auto. This fixes more cold-air calls than any part.

  • Thermostat set to Heat

    Set it to Heat and a few degrees above room temperature. Replace the batteries if the screen is dim or blank.

  • Give it a minute or two

    A furnace does not blow warm air right away. The inducer runs, the igniter heats, the burners light, and then the blower waits a little so the heat exchanger warms first. A short puff of cool air at start-up is normal.

  • Filter not clogged

    Pull the filter and hold it up to a light. If you cannot see light through it, replace it. A choked filter makes the furnace overheat and shut the burners off.

  • Gas shutoff open

    The handle on the gas line should sit in line with the pipe. Crosswise means closed. Check that another gas appliance, like the stove, works.

Likely causes

Ranked by how often they are the problem

  1. 1

    Clogged filter

    DIY fix

    Not enough air moves across the heat exchanger, so it overheats. The high limit switch shuts the burners off while the blower keeps running to cool things down. The air goes from warm to cool.

    Fix the air filter5–15 min$5–$25
  2. 2

    Flame sensor

    DIY fix

    The burners light, then go out a few seconds later. A dirty sensor cannot prove the flame, so the board shuts the gas off. You get a flash of heat and then cool air.

    Fix the flame sensor10–20 min$10–$50
  3. 3

    Hot surface igniter

    DIY fix

    The furnace tries to start, but nothing lights the gas. The inducer runs, there is no orange glow at the igniter, and no heat ever reaches the vents.

    Fix the igniter15–30 min$15–$80
  4. 4

    High limit switch

    DIY fix

    The limit switch has tripped or failed open. With a clean filter and open vents, a weak limit switch can cut the burners even when the furnace is not too hot.

    Fix the limit switch20–40 min$20–$80
  5. 5

    Pressure switch

    DIY fix

    The inducer runs but the igniter never glows. The board is waiting for the pressure switch to close. A blocked vent or a cracked hose can be the real cause.

    Fix the pressure switch20–45 min$20–$100
  6. 6

    Gas supply or gas valve

    Call a pro

    The igniter glows bright, but the gas never lights. Gas is not reaching the burners. Check the shutoff is open, then stop.

  7. 7

    Control board

    DIY fix

    The other parts check out, but the start-up sequence stops partway or never begins. The board runs every step, so it is the last thing to suspect.

    Fix the control board30 min–1.3 hr$50–$300

What's happening

What your furnace is doing

Check the thermostat fan setting first. On On, the blower runs all the time, even when the burners are off. Between heating cycles that air feels cool. Set it to Auto and the blower only runs when there is heat to move.

If the fan is on Auto and the air is still cold, the burners are not making heat. The furnace may be trying to light and failing, lighting and dropping out, or shutting down because it got too hot. When it overheats, a safety switch shuts the burners off but the blower keeps running to cool it down, so the vents blow cool air.

Stand by the furnace for one start-up. Listen for the small inducer fan, look for an orange glow, and watch for flame through the sight glass. Where the sequence stops tells you which part to look at.

Know your limits

When to call a pro

Stop and call a pro if

  • You smell gas. Leave the house and call your gas utility from outside.
  • The igniter glows bright orange but the burners never light.
  • The burners light with a bang, a puff of flame, or flames that roll out toward you.
  • The high limit keeps tripping with a clean filter and open vents. Something is restricting airflow or overheating the heat exchanger.
  • Your carbon monoxide alarm goes off. Get everyone outside to fresh air, then call 911 or the fire department.

FAQ

Common questions

Why does my furnace blow cold air between cycles?

Check the thermostat fan setting. On On, the blower runs all the time, so between heating cycles it moves unheated air. Set it to Auto and the blower only runs when the burners have warmed things up.

Why does the air start warm and then turn cold?

Usually the furnace is overheating. A clogged filter or closed vents trap heat, the high limit switch shuts the burners off, and the blower keeps running to cool the heat exchanger. Start with the air filter.

If the burners go out within seconds of lighting instead, look at the flame sensor.

How long should it take to get warm air?

Usually a minute or two after the thermostat clicks. The inducer runs first, then the igniter heats and the burners light. The blower waits after that so it does not push cold air, often around 30 seconds to a minute depending on the furnace. Check your unit's manual for its exact timing. If the air stays cool for several minutes, something in that sequence is failing.

Can a dirty filter really stop the heat?

Yes. A choked filter starves the furnace of air, it overheats, and a safety switch shuts the burners off. The blower keeps running, so the vents blow cool air. It is a one-minute check and the cheapest fix there is.