WhatsBusted
Symptom

Furnace lights, then shuts off after a few seconds

Good news: the hard part is working. The igniter glows and the burners light. Something just is not convincing the board to keep the gas on, and the usual fix costs next to nothing.

Check these first

Five-minute checks, no tools

  • Time the shutdown

    Watch one start-up through the sight glass and count. Seconds points to the flame sensor. Several minutes points to airflow, the high limit or the vent.

  • Filter not clogged

    Pull the filter and hold it up to a light. If you cannot see light through it, replace it. A choked filter makes the furnace overheat and shut down.

  • Supply vents open

    Walk the house and open any closed or blocked vents and returns. Furniture and rugs over vents count.

  • Vent pipes clear

    If your furnace vents through plastic pipes on an outside wall, check them for snow, ice, leaves or nests.

  • Doors seated

    Make sure both furnace doors are on and fully seated. A door that is not seated properly can let the door switch cut the power.

Likely causes

Ranked by how often they are the problem

  1. 1

    Dirty flame sensor

    DIY fix

    The burners light and go out within a few seconds, usually well under 10, every time. A thin film on the sensor rod weakens the signal, so the board never sees the flame. Cleaning it fixes this more often than anything else.

    Fix the flame sensor10–20 min$10–$50
  2. 2

    Pressure switch dropping out

    DIY fix

    If the pressure switch opens while the burners are lit, the board shuts the gas off. A switch that only just closes can drop out again, often because of a partly blocked vent, water in the hose or a weak inducer.

    Fix the pressure switch20–45 min$20–$100
  3. 3

    High limit switch tripping

    DIY fix

    The burners run for several minutes, not seconds, then shut off while the blower keeps going. The furnace is getting too hot, most often from a clogged filter, closed vents or a weak blower. The limit switch is doing its job.

    Fix the limit switch20–40 min$20–$80
  4. 4

    Poor ground or reversed polarity

    DIY fix

    The flame signal needs a solid ground path back to the board. A loose ground wire, or hot and neutral swapped at the furnace, can make even a clean sensor read as no flame. Many boards have a flash code for reversed polarity. With the power off you can check that the ground wires are tight. Fixing swapped wiring is a job for a pro or an electrician.

    Fix the control board30 min–1.3 hr$50–$300
  5. 5

    Flame not reaching the sensor

    Call a pro

    Only some burners light, or the flame looks lazy, yellow or lifted, so it never fully wraps the sensor rod. Dirty or misaligned burners are a job for a pro.

  6. 6

    Low gas pressure or a failing gas valve

    Call a pro

    The flame is weak or uneven even with a clean sensor. Gas pressure and the gas valve are pro-only. Do not adjust anything on the valve.

What's happening

What your furnace is doing

Your furnace gets most of the way through its start-up. The inducer runs, the pressure switch closes, the igniter glows, the gas valve opens and the burners light. So far, so good.

Right after the burners light, the control board has to prove the flame is real. It does that through the flame sensor, a thin rod sitting in the flame. If the board does not get a strong enough signal within a few seconds, it shuts the gas off for safety. The burners go out, the inducer keeps running for a bit, and the board tries again.

Timing is your best clue. If the flame dies within about 10 seconds, every time, look at the flame sensor first. If the burners run for several minutes before they quit, the board is reacting to something else, usually overheating or a vent problem. That is a different problem with a different fix.

Know your limits

When to call a pro

Stop and call a pro if

  • You smell gas at any point. Do not touch any switches. Leave the house and call your gas utility from outside.
  • Your carbon monoxide alarm goes off. Get everyone outside to fresh air, then call 911 or the fire department from outside.
  • The burners still drop out with a clean or new flame sensor and a tight ground wire.
  • The flames look yellow, lazy, lifted off the burners, or only some burners light.
  • The burners light late with a bang or a puff of flame.
  • The high limit keeps tripping even with a new filter and open vents. Something is still wrong with airflow or the burners, and a pro needs to find it.

FAQ

Common questions

Why does my furnace light and then shut off right away?

Almost always because the control board cannot prove the flame. A dirty flame sensor is the top cause by far. Clean it first. It costs almost nothing and takes about 15 minutes.

It runs for a few minutes and then shuts off. Is that the flame sensor?

Probably not. A flame sensor problem shows up within seconds. Several minutes of running usually means the furnace is overheating and the high limit switch is shutting the burners off. Start with the filter and the vents. See short cycling for more.

How many times will it try before it gives up?

It depends on the board, so check your unit's label or manual. Many try about three times, then lock out for a while, often around an hour, before trying again on their own. Switching the power off briefly and back on usually clears a lockout sooner. Do not keep cycling it over and over.

Is it dangerous when the furnace keeps shutting off?

Usually this is the furnace being careful. Shutting the gas off when it cannot prove a flame is a safety feature, so the usual result is no heat. If you ever smell gas, though, do not touch any switches. Leave and call your gas utility from outside.

Related

Keep going