Good news: a blinking light is the furnace telling you what went wrong. Count the flashes, find the chart, and you know which part to look at.
Check these first
Five-minute checks, no tools
Record the code first
Count the flashes and write the code down while the blower door is still on. Many boards erase the code when the power goes off or the door comes off.
Find your chart
Look for the code chart on a sticker on one of the furnace doors, often the blower door. No sticker? Search for your furnace's installation manual by the model number on the rating plate.
Doors fully seated
The blower door presses a safety switch that cuts power to the furnace when the door is off or loose. Push it firmly into place.
Check the filter
A limit or overheating code often traces back to a clogged filter. Hold it up to a light. If you cannot see light through it, replace it.
Vent pipes clear
Pressure switch codes often mean the exhaust or intake is blocked. Check plastic vent pipes on an outside wall for snow, ice, leaves or nests.
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Flame sensor (ignition or flame lockout)
Codes for ignition lockout, failure to prove flame or a low flame signal. If the burners light and then go out a few seconds later, a dirty flame sensor is the usual cause.
Fix the flame sensor10–20 min$10–$50 - 2DIY fix
Pressure switch
Codes for a pressure switch that did not close, or one stuck closed. Often the real cause is a blocked vent, a cracked or wet hose, or a weak inducer, not the switch itself.
Fix the pressure switch20–45 min$20–$100 - 3DIY fix
Hot surface igniter
An ignition failure or lockout code with no orange glow at start-up. A cracked igniter cannot light the gas.
Fix the igniter15–30 min$15–$80 - 4DIY fix
High limit switch
A limit circuit open code. The furnace got too hot, usually because of a clogged filter, closed vents or a weak blower. Fix the airflow first, then test the switch.
Fix the limit switch20–40 min$20–$80 - 5DIY fix
Inducer motor
A pressure switch code where the small fan on top does not start, hums, or runs slowly. Without a strong draft, the pressure switch never closes.
Fix the inducer motor1 hr–2 hr$100–$500 - 6DIY fix
Control board
No light at all with power confirmed on, a code for an internal board fault, or the same code coming back after the part it points to has been fixed.
Fix the control board30 min–1.3 hr$50–$300 - 7Call a pro
Wiring polarity or ground
A code for reversed polarity or a poor ground. The line voltage wiring to the furnace is connected backward or the ground is weak. That is electrical work for a pro.
- 8Call a pro
Gas valve
A code for flame sensed with no call for heat. The board sees flame when the gas should be off, which can mean a gas valve that is not closing fully. Switch the furnace off and call a pro.
What's happening
What your furnace is doing
Most furnaces have a small LED on the control board. On many models you can see it through a small window in the blower door. Leave that door on: taking it off cuts power to the board and can erase the code.
When a step of the start-up fails, the board flashes a pattern, usually a count of flashes and then a pause. Some boards use short and long flashes, or two lights in different colors. The chart that explains them is usually a sticker on a furnace door or in the installation manual.
The same count can mean different things on different furnaces. Even the normal light varies: on many boards a steady light or a slow blink means all is well, but not on all of them. Always use the chart for your furnace, not a chart from the internet.
Write the code down before you switch the power off or take a door off. On many boards, cutting power clears the code. A furnace in lockout may reset itself after a while, but a code that keeps coming back means a real fault.
Know your limits
When to call a pro
Stop and call a pro if
- You smell gas. Leave the house and call your gas supplier from outside.
- The code means flame sensed with no call for heat, or the burners stay lit when they should be off.
- The code points to reversed polarity, a poor ground or a wiring fault.
- A flame rollout code or a tripped rollout switch.
- The same code keeps coming back after you have fixed the part it points to.
FAQ
Common questions
What does a steady or slowly blinking light mean?
On many boards, a steady light or a slow, even blink means normal operation, or at least that the board has power. On some boards, though, a steady light means a board fault. Your chart will say which. No light at all usually means no power to the board: check the service switch, the breaker and that the blower door is seated.
Does resetting the furnace fix the error code?
Switching the power off and back on clears a lockout so the furnace can try again. It does not fix the cause. Write the code down first, then reset once and watch what happens. If the same code comes back, fix the part it points to or call a pro.
Why does my furnace code mean something different online?
Flash codes are not standard. Each furnace maker, and sometimes each board, uses its own list. Use the chart on your furnace door or in its manual. Generic charts online are a guess at best.
Is it safe to keep resetting a furnace that is locked out?
Reset it once to watch what it does, then stop. A lockout is a safety shutdown after failed tries, and resetting clears it without fixing anything. A code that keeps coming back means a real fault that needs fixing or a pro, not more resets. If you smell gas at any point, leave the house first.
Related
Keep going
- SymptomFurnace clicks but won't igniteThe inducer runs and the gas valve clicks, but the burners never light. After a few tries the furnace locks out. The usual culprit is a cracked igniter.Open guide
- SymptomFurnace lights, then shuts off after a few secondsThe burners light, then go out a few seconds later. The furnace waits, tries again, and eventually locks out. A dirty flame sensor is the usual cause, and cleaning it is a 15-minute job.Open guide
- SymptomInducer runs but the furnace never tries to lightThe draft inducer starts and keeps running, but the igniter never glows. The board is waiting for the pressure switch to say the vent is clear. Check the vent pipes and the switch hose first.Open guide
- SymptomFurnace won't turn on at allNothing happens when the thermostat calls for heat. The cause is usually a switch, a breaker, the thermostat or a loose blower door. After that, look at the board fuse and the control board.Open guide
- Furnace partControl boardThe control board runs the furnace's start-up sequence and flashes a code when something fails. Read the blink code first, because most codes point at a part the board is reporting on.Open guide
- Furnace partPressure switchThe pressure switch proves the inducer fan is pulling exhaust out before the furnace is allowed to light. When it stays open, the inducer runs and nothing else happens. Often the real fix is a clear hose or vent.Open guide
- Furnace partFlame sensorThe flame sensor is a thin metal rod that proves the burners are really lit. A dirty one is a classic reason a furnace lights and then shuts off seconds later. Cleaning it, or swapping it, is a one-screw job.Open guide
- Furnace partHigh limit switchThe high limit switch shuts the burners off if the furnace gets too hot. It trips most often because of poor airflow, so check the filter and the blower before you replace it.Open guide