Symptom

Inducer runs but the furnace never tries to light

The small fan starts, hums, and nothing else happens. No glow, no click. That tells you exactly where the start-up stalls, and it is usually a vent or a little rubber hose.

Check these first

Five-minute checks, no tools

  • Outside vent pipes clear

    If your furnace vents through plastic pipes on an outside wall or the roof, check both pipes for snow, ice, leaves, nests or a cap that blew shut.

  • Read the blink code

    Look through the small window in the lower door at the board's light. Count the flashes and match them to the chart on the door. A pressure switch code confirms you are in the right place.

  • Look at the small hose

    With the power off and the upper door removed, find the thin rubber hose between the inducer and the pressure switch. Look for cracks, a kink, a loose end or water sitting in it. Put the door back on before you run the furnace again.

  • Filter not clogged

    A clogged filter is not the usual cause here, but it takes a minute to check. Hold it up to a light. If you cannot see through it, replace it.

  • Reset and watch

    Turn the furnace off at the service switch for about 10 seconds, then back on. Watch one start-up and note how long the inducer runs before anything else happens.

Likely causes

Ranked by how often they are the problem

  1. 1

    Pressure switch, hose or port

    DIY fix

    The switch never closes, so the board never lights the igniter. Often the switch is fine and the real problem is its hose: cracked, kinked, full of water, or plugged at the port on the inducer.

    Fix the pressure switch20–45 min$20–$100
  2. 2

    Blocked vent or intake pipe

    DIY fix

    Snow, ice, leaves or a nest in the vent or the fresh-air intake chokes the draft. The inducer runs but cannot pull enough suction to close the switch. Clear what you can reach from outside, by hand.

  3. 3

    Clogged condensate drain

    DIY fix

    High-efficiency furnaces make water as they run. If the drain trap or its tubing clogs, water backs up into the inducer or the pressure hose and the switch cannot close. You may hear water sloshing when the inducer starts, or find water in the hose.

  4. 4

    Weak inducer motor

    DIY fix

    The inducer spins, but slowly, or it sounds rough. A weak inducer cannot pull enough draft to close the switch.

    Fix the inducer motor1 hr–2 hr$100–$500
  5. 5

    Control board

    DIY fix

    The switch closes and tests good, but the board still never moves on to the igniter. This is rarer, so rule out the switch, hose and vent first.

    Fix the control board30 min–1.3 hr$50–$300
  6. 6

    Vent problem inside the house

    Call a pro

    A vent pipe inside the house that is sagging, disconnected or blocked upsets the draft too. If you see a loose or broken vent pipe, or soot around the furnace, turn it off and call a pro. Venting is not a DIY repair.

What's happening

What your furnace is doing

Every start-up begins the same way. The thermostat calls for heat and the board starts the draft inducer, the small fan that pushes exhaust up the vent. Then it waits for the pressure switch to close.

The pressure switch feels the suction the inducer makes. When it feels enough, it closes and the board moves on to the igniter. If the suction is too weak, or the switch never gets the message, the board just waits. The inducer keeps humming and nothing lights.

After a while, many boards give up and flash a code for the pressure switch. That code is a strong clue. The usual reasons are a blocked vent, a cracked or water-filled hose, a clogged port, or a switch that has failed.

Know your limits

When to call a pro

Stop and call a pro if

  • You smell gas. Do not touch any switches. Leave the house and call your gas utility from outside.
  • You smell exhaust in the house. Turn the furnace off and call a pro.
  • A vent pipe inside the house is loose, disconnected or cracked.
  • You see soot, scorch marks or rust around the furnace or the vent.
  • Your carbon monoxide alarm goes off. Get everyone outside to fresh air, then call 911 or the fire department from outside.
  • The vent is clear, the hose is good and a new pressure switch still does not close.

FAQ

Common questions

Why does my furnace fan run but it won't ignite?

If the small fan on the burner side runs and nothing glows, the board is waiting on the pressure switch. Check the outside vent pipes, then the small hose to the switch. Those two fix most cases.

If the big fan behind the lower door runs instead, that is the blower, a different problem. See blowing cold air.

Can I jumper the pressure switch to get heat?

No. Never bypass a pressure switch. It is there to stop the furnace from running when exhaust cannot get out, and exhaust carries carbon monoxide. Find out why it is not closing instead.

What does the pressure switch blink code look like?

It depends on the board, and the same number of flashes can mean different things on different furnaces. Always check the chart on the inside of the blower door. See blinking error codes for how to read it.

There is water in the pressure switch hose. Is that bad?

It is a common cause on high-efficiency furnaces. Water there usually means the condensate drain or trap is slow or clogged. Clearing the drain is often the fix. The pressure switch guide shows how to check the hose and port.