Inducer runs but the furnace never tries to light
The small fan starts, hums, and nothing else happens. No glow, no click. That tells you exactly where the start-up stalls, and it is usually a vent or a little rubber hose.
Check these first
Five-minute checks, no tools
Outside vent pipes clear
If your furnace vents through plastic pipes on an outside wall or the roof, check both pipes for snow, ice, leaves, nests or a cap that blew shut.
Read the blink code
Look through the small window in the lower door at the board's light. Count the flashes and match them to the chart on the door. A pressure switch code confirms you are in the right place.
Look at the small hose
With the power off and the upper door removed, find the thin rubber hose between the inducer and the pressure switch. Look for cracks, a kink, a loose end or water sitting in it. Put the door back on before you run the furnace again.
Filter not clogged
A clogged filter is not the usual cause here, but it takes a minute to check. Hold it up to a light. If you cannot see through it, replace it.
Reset and watch
Turn the furnace off at the service switch for about 10 seconds, then back on. Watch one start-up and note how long the inducer runs before anything else happens.
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Pressure switch, hose or port
The switch never closes, so the board never lights the igniter. Often the switch is fine and the real problem is its hose: cracked, kinked, full of water, or plugged at the port on the inducer.
Fix the pressure switch20–45 min$20–$100 - 2DIY fix
Blocked vent or intake pipe
Snow, ice, leaves or a nest in the vent or the fresh-air intake chokes the draft. The inducer runs but cannot pull enough suction to close the switch. Clear what you can reach from outside, by hand.
- 3DIY fix
Clogged condensate drain
High-efficiency furnaces make water as they run. If the drain trap or its tubing clogs, water backs up into the inducer or the pressure hose and the switch cannot close. You may hear water sloshing when the inducer starts, or find water in the hose.
- 4DIY fix
Weak inducer motor
The inducer spins, but slowly, or it sounds rough. A weak inducer cannot pull enough draft to close the switch.
Fix the inducer motor1 hr–2 hr$100–$500 - 5DIY fix
Control board
The switch closes and tests good, but the board still never moves on to the igniter. This is rarer, so rule out the switch, hose and vent first.
Fix the control board30 min–1.3 hr$50–$300 - 6Call a pro
Vent problem inside the house
A vent pipe inside the house that is sagging, disconnected or blocked upsets the draft too. If you see a loose or broken vent pipe, or soot around the furnace, turn it off and call a pro. Venting is not a DIY repair.
What's happening
What your furnace is doing
Every start-up begins the same way. The thermostat calls for heat and the board starts the draft inducer, the small fan that pushes exhaust up the vent. Then it waits for the pressure switch to close.
The pressure switch feels the suction the inducer makes. When it feels enough, it closes and the board moves on to the igniter. If the suction is too weak, or the switch never gets the message, the board just waits. The inducer keeps humming and nothing lights.
After a while, many boards give up and flash a code for the pressure switch. That code is a strong clue. The usual reasons are a blocked vent, a cracked or water-filled hose, a clogged port, or a switch that has failed.
Know your limits
When to call a pro
Stop and call a pro if
- You smell gas. Do not touch any switches. Leave the house and call your gas utility from outside.
- You smell exhaust in the house. Turn the furnace off and call a pro.
- A vent pipe inside the house is loose, disconnected or cracked.
- You see soot, scorch marks or rust around the furnace or the vent.
- Your carbon monoxide alarm goes off. Get everyone outside to fresh air, then call 911 or the fire department from outside.
- The vent is clear, the hose is good and a new pressure switch still does not close.
FAQ
Common questions
Why does my furnace fan run but it won't ignite?
If the small fan on the burner side runs and nothing glows, the board is waiting on the pressure switch. Check the outside vent pipes, then the small hose to the switch. Those two fix most cases.
If the big fan behind the lower door runs instead, that is the blower, a different problem. See blowing cold air.
Can I jumper the pressure switch to get heat?
No. Never bypass a pressure switch. It is there to stop the furnace from running when exhaust cannot get out, and exhaust carries carbon monoxide. Find out why it is not closing instead.
What does the pressure switch blink code look like?
It depends on the board, and the same number of flashes can mean different things on different furnaces. Always check the chart on the inside of the blower door. See blinking error codes for how to read it.
There is water in the pressure switch hose. Is that bad?
It is a common cause on high-efficiency furnaces. Water there usually means the condensate drain or trap is slow or clogged. Clearing the drain is often the fix. The pressure switch guide shows how to check the hose and port.
Related
Keep going
- SymptomFurnace clicks but won't igniteThe inducer runs and the gas valve clicks, but the burners never light. After a few tries the furnace locks out. The usual culprit is a cracked igniter.Open guide
- SymptomFurnace control board blinking an error codeThe light on the control board flashes a code when something fails. Count the flashes, match them to the chart inside the blower door, and write the code down before you reset anything.Open guide
- SymptomFurnace making loud or unusual noisesSqueals and grinding usually mean a worn motor or a loose blower wheel. Rattles mean something is loose. Humming points to a motor or capacitor. A boom at start-up is delayed ignition and needs a pro.Open guide
- Furnace partPressure switchThe pressure switch proves the inducer fan is pulling exhaust out before the furnace is allowed to light. When it stays open, the inducer runs and nothing else happens. Often the real fix is a clear hose or vent.Open guide
- Furnace partInducer motorThe inducer motor is the small fan that pulls exhaust through the furnace and out the vent before the burners light. When it wears out it gets loud, slows or stalls, and the furnace will not start.Open guide
- Furnace partControl boardThe control board runs the furnace's start-up sequence and flashes a code when something fails. Read the blink code first, because most codes point at a part the board is reporting on.Open guide