The furnace is trying. It runs its start-up checklist, gets to the lighting step, and fails. That narrows things down a lot.
Check these first
Five-minute checks, no tools
Thermostat set to Heat
Set it to Heat and a few degrees above room temperature. Replace the batteries if the screen is dim or blank.
Gas shutoff open
The handle on the gas line should sit in line with the pipe. Crosswise means closed. Check that another gas appliance, like the stove, works.
Filter not clogged
Pull the filter and hold it up to a light. If you cannot see light through it, replace it.
Vent pipes clear
If your furnace vents through plastic pipes on an outside wall, check them for snow, ice, leaves or nests. Brush away loose snow, but do not chip at ice.
Reset the lockout once
Turn the furnace off at the service switch for about 10 seconds, then back on. On many furnaces this clears the lockout so you can watch a fresh start-up.
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Hot surface igniter
No orange glow before the click. The igniter is cracked or burned out, so nothing lights the gas. This is the most common cause.
Fix the igniter15–30 min$15–$80 - 2DIY fix
Flame sensor
The burners do light, but only for a few seconds before they cut out. That quick flash of flame is easy to miss, so it can look like no ignition at all.
Fix the flame sensor10–20 min$10–$50 - 3Call a pro
Gas supply or gas valve
The igniter glows bright but the gas never lights. Gas is not reaching the burners, from low supply pressure or a valve that is not opening. Check the shutoff is open, then stop. Gas valve work is for a pro.
- 4Call a pro
Dirty or blocked burners
The burners light late, with a puff or a bang, or only some of them light. Burner cleaning means working on the gas train, so leave it to a pro.
- 5DIY fix
Control board
The igniter tests good but never gets power, or the sequence stops at random points. Read the board's blink code first. It often names the problem.
Fix the control board30 min–1.3 hr$50–$300
What's happening
What your furnace is doing
A furnace starts in a fixed order: the inducer fan spins up, the pressure switch closes, the igniter glows, the gas valve clicks open, and the burners light.
When you hear clicking but get no flame, the sequence is reaching the gas valve step and nothing is lighting the gas. The board notices there is no flame, closes the valve, waits, and tries again. After a few tries, commonly three, it locks out and flashes an error code. Many boards then wait about an hour before trying again on their own.
Watch one start-up through the sight glass or the door louvers. Whether you see an orange glow before the click tells you which half of the list below to look at.
If the inducer runs but the igniter never glows and you never hear the valve click, the furnace is stuck one step earlier. See inducer runs but won't light instead.
Know your limits
When to call a pro
Stop and call a pro if
- You smell gas. Do not touch any switches. Leave the house and call your gas utility from outside.
- Your carbon monoxide alarm goes off. Get everyone outside to fresh air, then call 911 or the fire department from outside.
- The igniter glows but the burners never light.
- The burners light with a bang, a puff of flame, or flames that roll out toward you.
- The furnace locks out again right after you replace the igniter.
- Other gas appliances in the house are not working either. Call your gas utility.
FAQ
Common questions
Why does my furnace click three times and then stop?
Each try usually ends with a click as the gas valve opens. Many control boards try three times, some a few more, so check your unit's label or manual. If none of them proves flame, the board locks out for safety, often for about an hour, or until you reset the power.
Is it safe to keep resetting the furnace?
Reset it once to watch what it does. Do not keep cycling it. The lockout is a safety feature, and if the cause is still there the board just locks out again. Find the cause instead.
What does the flashing light on the control board mean?
It is an error code. Count the flashes and look for the code chart, which is usually a sticker on the inside of a furnace door. See blinking light or error code for how to read it.
Could it just be a dirty filter?
A clogged filter more often causes short cycling than a failure to light. It is still the first thing to check, because it takes one minute and costs almost nothing.
Related
Keep going
- SymptomInducer runs but the furnace never tries to lightThe draft inducer starts and keeps running, but the igniter never glows. The board is waiting for the pressure switch to say the vent is clear. Check the vent pipes and the switch hose first.Open guide
- SymptomFurnace lights, then shuts off after a few secondsThe burners light, then go out a few seconds later. The furnace waits, tries again, and eventually locks out. A dirty flame sensor is the usual cause, and cleaning it is a 15-minute job.Open guide
- SymptomFurnace control board blinking an error codeThe light on the control board flashes a code when something fails. Count the flashes, match them to the chart inside the blower door, and write the code down before you reset anything.Open guide
- Furnace partPressure switchThe pressure switch proves the inducer fan is pulling exhaust out before the furnace is allowed to light. When it stays open, the inducer runs and nothing else happens. Often the real fix is a clear hose or vent.Open guide
- Furnace partAir filterThe air filter catches dust before it reaches the blower and heat exchanger. A clogged one chokes airflow, makes the furnace work harder and can trip it off on high heat. Check it monthly.Open guide