Furnace won't turn on at all
No hum, no fan, no click. That sounds bad, but it is often the easiest kind of problem. Most of the time the furnace simply is not getting power or a call for heat.
Check these first
Five-minute checks, no tools
Thermostat on Heat, with fresh batteries
Set it to Heat and a few degrees above room temperature. A blank or dim screen usually means dead batteries.
Service switch on
Look for a light switch on or near the furnace. It looks like a light switch, so it is easy to flip off by mistake. Make sure it is on.
Breaker not tripped
Check the furnace breaker in your panel. A tripped breaker sits in the middle. Push it fully off, then back on, one time only. If it trips again, leave it off and call a pro.
Blower door seated
The lower door presses a safety switch. If the door is loose or crooked, the furnace gets no power. Push it firmly into place. Never tape or bypass the switch.
Condensate pump not full
High-efficiency furnaces have plastic vent pipes and drain water to a small pump or floor drain. On many setups, a safety switch on the pump shuts the furnace off if the pump backs up. Look for a full pump or water around it. Never bypass that switch. Clear the drain or fix the pump instead.
Board light on or off
Look at the status light on the control board through the blower door window. No light means no power to the board. A blinking light is an error code.
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Tripped breaker or service switch off
The furnace has no power at all. The service switch got flipped off, or the breaker tripped. The board light is dark.
- 2DIY fix
Thermostat or thermostat wires
The board light is on, but the furnace never starts. The thermostat is not calling for heat. Dead batteries, the wrong mode, or a loose wire at the thermostat or the board are common.
- 3DIY fix
Door safety switch
The blower door is not pressing the switch. Usually the door is just not seated. Sometimes the switch itself is stuck or broken.
- 4DIY fix
Blown board fuse or control board
The furnace has power, but the board light is dark. A small fuse on the board protects the 24 volt circuit. It often blows when a thermostat wire shorts. A board that has failed outright is less common.
Fix the control board30 min–1.3 hr$50–$300 - 5DIY fix
Condensate float switch
On a high-efficiency furnace, a clogged drain line or a failed condensate pump lets water back up, and the pump's safety switch cuts the furnace off.
- 6DIY fix
High limit switch
The limit switch is stuck open or has failed. The board sees an overheat that is not there and will not light the burners. The board light often flashes a code for this. On many furnaces the blower also runs while the limit is open, so if you hear the fan, see blowing cold air.
Fix the limit switch20–40 min$20–$80 - 7Call a pro
Transformer
The transformer turns 120 volts into the 24 volts the board and thermostat use. If it fails, the board stays dark even with power at the furnace.
What's happening
What your furnace is doing
A furnace needs three things to start: 120 volt power, its own 24 volt control circuit, and a call for heat from the thermostat. If any one is missing, nothing happens at all. No inducer, no glow, no blower.
The status light on the control board helps you tell which. Look through the small window in the blower door, if it has one. A light that is on or blinking means the board has power. No light at all means the board has no power, or its fuse or transformer is out. Light patterns vary by furnace, so check the chart on the door.
Work from the outside in. Thermostat, then the service switch and breaker, then the blower door, then the light on the board. Most no-start calls end before you pick up a tool.
Know your limits
When to call a pro
Stop and call a pro if
- The breaker trips again when you reset it. Something is shorted.
- A new board fuse blows right away. A thermostat wire or a component is shorted.
- You smell burning, hear buzzing or arcing, or see melted wires or scorch marks inside the cabinet.
- You smell gas. Leave the house and call your gas utility from outside.
- Water is pooling under the furnace and you cannot find a clogged drain or a full pump.
FAQ
Common questions
Why is my furnace completely dead?
Almost always it has lost power or its call for heat. Check the thermostat batteries and mode, the service switch near the furnace, the breaker, and that the blower door is pushed firmly shut. Those four checks solve most dead furnaces.
The board light is off but the breaker is on. What now?
Check the service switch and the blower door first. Then look for a small blade fuse on the control board, like the ones in a car. If it is blown, something shorted the 24 volt circuit, often a thermostat wire. Fix the short before you replace the fuse, or the new one will blow too. Use the same rating that is printed on the board or the old fuse. Never fit a bigger one.
Does a furnace have a reset button?
Most do not have one big reset button. Switching the power off at the service switch for a short time and back on resets the control board after a lockout. If it locks out again, find the cause instead of resetting it over and over. Some furnaces have a small reset button on a rollout switch near the burners. If that one has tripped, the furnace got too hot where the flame is, so call a pro instead of resetting it.
Can a dirty filter stop a furnace from turning on?
Not usually from a dead start. A clogged filter more often makes a running furnace overheat and short cycle. If the board light is blinking a limit code, though, change the filter first.
Related
Keep going
- SymptomFurnace control board blinking an error codeThe light on the control board flashes a code when something fails. Count the flashes, match them to the chart inside the blower door, and write the code down before you reset anything.Open guide
- SymptomFurnace blower won't turn onThe big fan that pushes warm air to your vents does not start. A humming motor that never spins points to the run capacitor. Silence points to the door switch, a fuse, the board or the motor.Open guide
- SymptomInducer runs but the furnace never tries to lightThe draft inducer starts and keeps running, but the igniter never glows. The board is waiting for the pressure switch to say the vent is clear. Check the vent pipes and the switch hose first.Open guide
- Furnace partControl boardThe control board runs the furnace's start-up sequence and flashes a code when something fails. Read the blink code first, because most codes point at a part the board is reporting on.Open guide
- Furnace partHigh limit switchThe high limit switch shuts the burners off if the furnace gets too hot. It trips most often because of poor airflow, so check the filter and the blower before you replace it.Open guide
- Furnace partAir filterThe air filter catches dust before it reaches the blower and heat exchanger. A clogged one chokes airflow, makes the furnace work harder and can trip it off on high heat. Check it monthly.Open guide