WhatsBusted
Symptom

Furnace won't turn on at all

No hum, no fan, no click. That sounds bad, but it is often the easiest kind of problem. Most of the time the furnace simply is not getting power or a call for heat.

Check these first

Five-minute checks, no tools

  • Thermostat on Heat, with fresh batteries

    Set it to Heat and a few degrees above room temperature. A blank or dim screen usually means dead batteries.

  • Service switch on

    Look for a light switch on or near the furnace. It looks like a light switch, so it is easy to flip off by mistake. Make sure it is on.

  • Breaker not tripped

    Check the furnace breaker in your panel. A tripped breaker sits in the middle. Push it fully off, then back on, one time only. If it trips again, leave it off and call a pro.

  • Blower door seated

    The lower door presses a safety switch. If the door is loose or crooked, the furnace gets no power. Push it firmly into place. Never tape or bypass the switch.

  • Condensate pump not full

    High-efficiency furnaces have plastic vent pipes and drain water to a small pump or floor drain. On many setups, a safety switch on the pump shuts the furnace off if the pump backs up. Look for a full pump or water around it. Never bypass that switch. Clear the drain or fix the pump instead.

  • Board light on or off

    Look at the status light on the control board through the blower door window. No light means no power to the board. A blinking light is an error code.

Likely causes

Ranked by how often they are the problem

  1. 1

    Tripped breaker or service switch off

    DIY fix

    The furnace has no power at all. The service switch got flipped off, or the breaker tripped. The board light is dark.

  2. 2

    Thermostat or thermostat wires

    DIY fix

    The board light is on, but the furnace never starts. The thermostat is not calling for heat. Dead batteries, the wrong mode, or a loose wire at the thermostat or the board are common.

  3. 3

    Door safety switch

    DIY fix

    The blower door is not pressing the switch. Usually the door is just not seated. Sometimes the switch itself is stuck or broken.

  4. 4

    Blown board fuse or control board

    DIY fix

    The furnace has power, but the board light is dark. A small fuse on the board protects the 24 volt circuit. It often blows when a thermostat wire shorts. A board that has failed outright is less common.

    Fix the control board30 min–1.3 hr$50–$300
  5. 5

    Condensate float switch

    DIY fix

    On a high-efficiency furnace, a clogged drain line or a failed condensate pump lets water back up, and the pump's safety switch cuts the furnace off.

  6. 6

    High limit switch

    DIY fix

    The limit switch is stuck open or has failed. The board sees an overheat that is not there and will not light the burners. The board light often flashes a code for this. On many furnaces the blower also runs while the limit is open, so if you hear the fan, see blowing cold air.

    Fix the limit switch20–40 min$20–$80
  7. 7

    Transformer

    Call a pro

    The transformer turns 120 volts into the 24 volts the board and thermostat use. If it fails, the board stays dark even with power at the furnace.

What's happening

What your furnace is doing

A furnace needs three things to start: 120 volt power, its own 24 volt control circuit, and a call for heat from the thermostat. If any one is missing, nothing happens at all. No inducer, no glow, no blower.

The status light on the control board helps you tell which. Look through the small window in the blower door, if it has one. A light that is on or blinking means the board has power. No light at all means the board has no power, or its fuse or transformer is out. Light patterns vary by furnace, so check the chart on the door.

Work from the outside in. Thermostat, then the service switch and breaker, then the blower door, then the light on the board. Most no-start calls end before you pick up a tool.

Know your limits

When to call a pro

Stop and call a pro if

  • The breaker trips again when you reset it. Something is shorted.
  • A new board fuse blows right away. A thermostat wire or a component is shorted.
  • You smell burning, hear buzzing or arcing, or see melted wires or scorch marks inside the cabinet.
  • You smell gas. Leave the house and call your gas utility from outside.
  • Water is pooling under the furnace and you cannot find a clogged drain or a full pump.

FAQ

Common questions

Why is my furnace completely dead?

Almost always it has lost power or its call for heat. Check the thermostat batteries and mode, the service switch near the furnace, the breaker, and that the blower door is pushed firmly shut. Those four checks solve most dead furnaces.

The board light is off but the breaker is on. What now?

Check the service switch and the blower door first. Then look for a small blade fuse on the control board, like the ones in a car. If it is blown, something shorted the 24 volt circuit, often a thermostat wire. Fix the short before you replace the fuse, or the new one will blow too. Use the same rating that is printed on the board or the old fuse. Never fit a bigger one.

Does a furnace have a reset button?

Most do not have one big reset button. Switching the power off at the service switch for a short time and back on resets the control board after a lockout. If it locks out again, find the cause instead of resetting it over and over. Some furnaces have a small reset button on a rollout switch near the burners. If that one has tripped, the furnace got too hot where the flame is, so call a pro instead of resetting it.

Can a dirty filter stop a furnace from turning on?

Not usually from a dead start. A clogged filter more often makes a running furnace overheat and short cycle. If the board light is blinking a limit code, though, change the filter first.