Water heater dip tube: check and replace

Hot water that turns lukewarm fast, plus little white plastic bits in your faucet screens? A broken dip tube is a cheap part and an afternoon job.

Difficulty
Moderate
Time
1 hr–2 hr
Typical part cost
$10–$60Pro: $100–$300

One plumbing connection and a threaded nipple. The work is in draining, getting the cold line off without damaging anything, and sealing it back up.

What it does

What the dip tube does

The dip tube is a plastic tube that hangs down inside the tank from the cold water inlet on top. Gas and electric tank heaters both have one. On many heaters it is one piece with the inlet nipple.

It sends incoming cold water down to the bottom of the tank, where the heat is applied. That keeps the cold water from mixing with the hot water waiting at the top, where it leaves for your taps.

Why it fails

If the tube cracks, breaks off short or falls apart, cold water comes out near the top of the tank. It mixes with the hot water right where your taps draw from, so the hot water seems to run out much sooner.

Heaters built in the mid-1990s are the classic case. Millions of dip tubes made from about 1993 to 1997 could slowly fall apart and send small white plastic bits into the plumbing.

Symptoms

Signs of a bad dip tube

  • Hot water runs out fast

    The water starts hot and turns lukewarm much sooner than it used to, even though the heater is working.

    Full diagnosis
  • White plastic bits in faucet screens

    Small white flakes or chips clog faucet aerators, showerheads or appliance screens. Those can be pieces of a dip tube that is falling apart.

  • Weaker hot water flow

    Bits of a broken tube can clog screens and lower the flow of hot water at your taps.

How to test it

Test the dip tube before you buy

Look it overNo meter needed
  1. With the heater off, the cold supply closed and the tank drained below the inlet, take out the inlet nipple and dip tube.
  2. Look along the whole tube for cracks, holes or a broken-off end.
  3. Check that nothing is blocking it.
Good
The tube is whole, with no cracks and no blockage, and about as long as a new one for your model. The problem is likely elsewhere. Reinstall it with fresh thread sealant.
Bad
Any crack, hole or missing length. Manufacturers say a cracked tube cannot be repaired in place. Replace it.

Safety first

Before you touch anything

  1. 1

    Turn off the power or the gas

    Electric heater: turn off its breaker, then hold a voltage tester to the power cable where it enters the heater. Try the tester on a live outlet first. Gas heater: turn the gas control to OFF or PILOT as the label on the heater says.

  2. 2

    Close the gas shutoff (gas heaters)

    Turn the handle on the gas line to the heater so it sits crosswise to the pipe. You will not open any gas fittings in this job.

  3. 3

    Shut off the cold water

    Close the cold water supply valve to the heater, then open a hot water faucet nearby to let the pressure out.

  4. 4

    Let it cool

    The water and the fittings on top can be hot enough to burn, and an insulated tank stays hot for hours. Give it at least a couple of hours with the heat off and wear gloves.

    Wait about 120 min

  5. 5

    Drain below the inlet

    Drain enough water that the level is below the cold inlet. One manufacturer says at least 5 gallons.

Tools you'll need

Grab these first

Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works

See the full repair tool kit

Step by step

How to replace the dip tube

  1. 1

    Turn off the power, or the gas

    Electric heater: turn off the water heater's breaker. Confirm with a voltage tester at the power cable where it enters the heater.

    Gas heater: turn the gas control to OFF or PILOT, as the label on the heater says. Then turn the gas shutoff handle on the line so it sits crosswise to the pipe.

    Careful. An electric heater must stay off until the tank is full again. A heating element that runs dry can burn out.

  2. 2

    Shut off the cold water and open a hot tap

    Close the cold water supply valve on the pipe that feeds the heater.

    Open a hot water faucet nearby to let the pressure out of the tank.

  3. 3

    Drain below the inlet

    Run a garden hose from the drain valve to a floor drain or outside. Open the valve and let the water level drop below the top of the tank, then close it.

    One manufacturer says to drain at least 5 gallons.

    Careful. The water can be hot enough to scald. Keep the hose end where it cannot splash anyone.

  4. 4

    Disconnect the cold water line

    Find the cold inlet on top of the tank. Follow the pipe from the cold shutoff valve you just closed to where it meets the tank.

    Loosen the cold line where it connects to the inlet nipple with a wrench and move it aside.

    Tip. Take a photo of the connections first. It is your reference for putting them back.

  5. 5

    Unscrew the inlet nipple

    Turn the inlet nipple counterclockwise with channel-lock pliers or a pipe wrench. Grip the body of the nipple, not its threads, so you do not damage them.

    On many heaters the dip tube is attached to the nipple and comes out with it.

  6. 6

    Pull out the old tube

    Lift the tube straight up and out of the tank.

    If the tube stays in the tank after the nipple is out, hold a screwdriver at an angle against the inside of the tube and use friction to draw it up.

    Look it over. Any crack, hole or missing length means replace it.

  7. 7

    Match the new tube

    Get a replacement that matches the inlet thread size and the tube length for your heater. Many come as one piece with a new inlet nipple. The parts list for your model number has the right one.

    If your old inlet had a heat trap insert, make sure the new part has one too.

    Tip. Cross-linked polyethylene tubes hold up well in hot water.

  8. Buy the part

    Dip tube

    Opens AppliancePartsPros in a new tab. Where’s my model number?

    What to look for

    • The inlet thread size and tube length listed for your heater's model number.
    • A tube that comes with its inlet nipple if your old one was one piece, and a heat trap insert if the old inlet had one.
    • Cross-linked polyethylene, which holds up in hot water.

    Generic dip tubes are sold by length and can fit many heaters. Check your warranty first. A defective tube on a newer heater may be covered.

  9. 8

    Install the new tube and nipple

    Wrap the nipple threads with PTFE tape or coat them with pipe dope. Lower the tube gently into the inlet and thread the nipple in by hand.

    Tighten it with the pliers until it is snug. Do not overtighten.

  10. 9

    Reconnect the cold line

    Thread the cold line back onto the inlet nipple and tighten it with the wrench. Check it against your photo.

  11. 10

    Refill and check for leaks

    Make sure the drain valve is closed. Leave the hot faucet open and turn the cold supply back on.

    When water runs from the faucet in a steady stream with no sputtering, the tank is full. Close the faucet and check the inlet connection for drips.

  12. 11

    Turn the heat back on

    Electric heater: only once the tank is full, turn the breaker back on.

    Gas heater: open the gas shutoff so the handle lines up with the pipe, then follow the lighting instructions on the heater's label.

    Rinse out any faucet aerators and showerhead screens that collected plastic bits.

Buy the part

Get the right replacement

Buy the part

Dip tube

Opens AppliancePartsPros in a new tab. Where’s my model number?

What to look for

  • The inlet thread size and tube length listed for your heater's model number.
  • A tube that comes with its inlet nipple if your old one was one piece, and a heat trap insert if the old inlet had one.
  • Cross-linked polyethylene, which holds up in hot water.

Generic dip tubes are sold by length and can fit many heaters. Check your warranty first. A defective tube on a newer heater may be covered.

Know your limits

When to call a pro

Stop and call a pro if

  • You smell gas near a gas water heater. Do not touch any switches. Leave the house and call your gas utility from outside.
  • The cold line is hard piped or soldered and does not come apart with a wrench.
  • The inlet nipple will not turn, or its threads or the tank fitting look damaged.
  • A new dip tube does not bring back your hot water. Something else is wrong, such as an element, a thermostat or the burner.
  • Water leaks from the tank itself rather than a fitting.

FAQ

Dip tube questions

How do I know it is the dip tube and not an element or thermostat?

White plastic bits in faucet screens are the strongest clue. Without them, check the cheaper suspects first: on an electric heater the heating elements and thermostats, and on any heater the temperature setting.

If you replace the dip tube and the hot water still runs out fast, the problem is elsewhere.

Do gas water heaters have a dip tube too?

Yes. Gas and electric tank heaters both feed cold water through a dip tube on the cold inlet. The job is the same. Only the shutoff steps at the start differ.

My heater is from the mid-1990s. Should I worry?

Maybe. Dip tubes made from about 1993 to 1997 were known to fall apart in the tank. If you see white plastic bits in faucet screens, the dip tube is the first thing to check.

Will the plastic bits hurt anything?

They clog faucet aerators, showerheads and appliance screens and can reduce your hot water flow. Rinse the screens after you replace the tube.