Heat strips not working on your air handler

The heat pump runs, but on a cold day the house never catches up, or Emergency heat blows cool air. The backup heat strips have stopped. Start with the breakers and the filter.

Check these first

Five-minute checks, no tools

  • Thermostat set to Heat

    Set the thermostat to Heat a few degrees above the room temperature. To test the strips alone, switch it to Emergency heat for a few minutes and feel the air at a vent. Then switch back, because strip heat costs more to run.

  • Every breaker on

    Check every breaker for the air handler in the house panel, plus any breakers on the front of the air handler and the disconnect switch beside it. The heat kit may be on a breaker of its own. If one trips again right away, leave it off and call a pro.

  • Filter clean

    A clogged filter cuts the airflow over the strips. They overheat and their limit switches shut them off. Hold the filter up to a light and replace it if you cannot see through it.

  • Blower running

    The strips need the blower moving air over them. If no air comes out of the vents at all, the strips are not the problem yet. See [no airflow](/air-handler/symptoms/no-airflow) first.

Likely causes

Ranked by how often they are the problem

  1. 1

    Heat strip breaker off or tripped

    DIY fix

    The heat pump and blower run, but a breaker that feeds the strips, in the panel or on the heat kit, is off or tripped. Reset it once. A breaker that trips again as soon as the strips come on points to a short in a strip or its wiring, so leave it off and call a pro.

  2. 2

    Heat sequencer

    DIY fix

    Power reaches the air handler and the thermostat calls for heat, but some or all of the strips never come on. A sequencer that has failed does not close its contacts, so those strips stay cold. A sequencer stuck closed can also leave strips running after the call ends.

    Fix the sequencer30 min–1.3 hr$40–$55
  3. 3

    Burned-out heat strip

    DIY fix

    One element has broken open, so it reads open on a meter with the power off. If the other strips still work, you may get some heat, just not enough.

    Fix the heat strips1 hr–2.5 hr$115–$275
  4. 4

    Strip limit tripped by low airflow

    DIY fix

    The strips come on, then cut out after a few minutes. Not enough air is crossing them, so they get too hot and the limit switch opens. A clogged filter is the usual reason. Fix the airflow before you blame the limit.

    Fix the air filter5–15 min$5–$25
  5. 5

    Control board

    DIY fix

    The thermostat calls for heat, but the low-voltage signal never reaches the sequencer. The board or its wiring may not be passing the call through.

    Fix the control board30 min–1.5 hr$55–$270
  6. 6

    Thermostat setup or wiring

    DIY fix

    The thermostat is not set up for a heat pump with backup heat, or the wire for auxiliary heat is loose. This can happen after a new thermostat goes in.

What's happening

What your air handler is doing

A heat pump heats the house by moving heat in from outside. On the coldest days, and while the outdoor unit defrosts, the thermostat calls for auxiliary heat: electric resistance heat strips in the air handler.

Emergency heat is a thermostat setting that shuts the heat pump off and runs the strips alone. It is the easiest way to test them. If Emergency heat blows cool air, the strips are not heating.

When the thermostat calls for strip heat, a low-voltage signal reaches the heat sequencer. It switches the strips on one stage at a time, so they do not all draw power at once. Limit switches on the strips cut them off if they overheat.

The strips run on 240 V and draw a lot of current. Depending on the size of the heat kit, the air handler may be fed by more than one breaker in the house panel, and many heat kits also have breakers of their own on the front of the kit.

Know your limits

When to call a pro

Stop and call a pro if

  • A heat strip breaker trips again as soon as the strips come on.
  • You see smoke, scorch marks or melted wire near the strips or the sequencer, or you smell burning. Turn every breaker off and leave them off.
  • You are not comfortable working in a 240 V cabinet with more than one power supply, or you cannot confirm with a tester that every circuit is dead.
  • The strips run very often in mild weather. The heat pump itself may not be keeping up, or it may be defrosting too often.

FAQ

Common questions

What is the difference between auxiliary heat and emergency heat?

Auxiliary heat comes on by itself when the heat pump needs help. Emergency heat is a setting you choose by hand. It turns the heat pump off and runs only the backup heat. Use it only when the heat pump is not working, because it costs much more to run.

Is it normal for the heat strips to come on during defrost?

Yes. While the outdoor unit defrosts, most systems turn the strips on so the house does not get a blast of cool air. They turn off again when defrost ends.

Why does the heat strip breaker keep tripping?

A breaker that trips the moment the strips come on usually means a shorted strip or a wiring fault. Leave it off and have a pro find the cause. Resetting it again and again does not fix the fault.

Can I test the heat strips myself?

With every breaker and the disconnect off, and the power confirmed dead with a tester, a careful homeowner can check a strip with a multimeter. A good one shows continuity, an open one does not. The heat strips guide walks through it.