No air coming from your vents
The outdoor unit may be running, but nothing comes out of the vents. Most of the time the blower has stopped or something is choking the air. Start with the easy checks.
Check these first
Five-minute checks, no tools
Thermostat set and fan on
Make sure the thermostat is set to Cool or Heat and set below or above the room temperature. Then switch the fan from Auto to On. If the blower starts, the motor works and the problem is in the call from the thermostat or the board.
Breakers and disconnect on
Check the air handler's breakers in the panel and the disconnect or service switch at the unit. An air handler with heat strips may have more than one breaker. If a breaker trips again right after you reset it, leave it off and call a pro.
Blower door seated
The blower door presses a safety switch. If the door is loose or was put back crooked, the blower gets no power. Push it firmly into place. Never tape or bypass the switch.
Filter not clogged
Pull the filter and hold it up to a light. If you cannot see through it, replace it. A badly clogged filter starves the blower of air and can freeze the coil.
Registers open, returns clear
Walk the house. Open the supply registers and move furniture, rugs and boxes away from the return grilles. Closing a lot of vents cuts the airflow over the coil.
Float switch not tripped
Look for water in the pan under the unit, or a float switch on the drain line or pan that has lifted. If the pan is full, the float has shut the system off on purpose. See [water in the drain pan](/air-handler/symptoms/water-in-pan).
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Run capacitor
The blower hums but does not spin, or starts slowly. A weak capacitor cannot give the motor the push it needs to start. It is cheap, common and a careful homeowner can test and swap it with the power off and the capacitor discharged.
Fix the capacitor20–45 min$10–$50 - 2DIY fix
Clogged air filter
The blower runs but the air from the vents is weak. A filter packed with dust chokes the air going into the unit, and over time it can freeze the coil and make the blower overheat.
Fix the air filter5–15 min$5–$25 - 3DIY fix
Clogged drain tripped the float switch
Water has backed up into the pan and the float switch has shut the whole system off, blower included. Clearing the drain line usually lets the switch reset and the system run again.
Fix the condensate drain20–45 min$0–$10 - 4DIY fix
Stuck or failed float switch
The pan is dry and the drain runs freely, but the system stays off. A float that is stuck up or a switch that has failed keeps the system shut down.
Fix the float switch20–45 min$15–$50 - 5DIY fix
Blower motor
The capacitor tests good but the motor still will not run, or the wheel is stiff to turn by hand with the power off. Worn bearings or a burned-out motor mean a new motor. A motor with an electronics module and no capacitor is a variable-speed motor and is tested differently.
Fix the blower motor1 hr–2.5 hr$150–$450 - 6DIY fix
Blower door switch
If the door switch is not pressed, the air handler gets no power, so nothing runs. A loose door, a bent bracket or a failed switch can cause this.
- 7DIY fix
Control board
Power is on, the door is seated, the float is down and the capacitor is good, but the blower does not come on when the system calls for it, or only runs with the fan set to On. The board may not be switching the blower on.
Fix the control board30 min–1.5 hr$55–$270 - 8Call a pro
Coil frozen over
The blower runs but almost no air gets through because the coil is covered in ice. Turn the cooling off and run the fan to thaw it. If it freezes again after the filter is fixed, a pro should look for low refrigerant or a dirty coil.
What's happening
What your air handler is doing
An air handler is the indoor half of a central air or heat pump system. Its blower pulls house air in through the filter, pushes it across the indoor coil, and sends it out through the ducts to your vents.
When no air comes out, either the blower is not running or the air cannot get through. A steady hum with no spinning usually means the motor has power but cannot start, which is the classic sign of a weak run capacitor. No sound at all means power is not reaching the motor.
Two safety switches can also stop the blower on purpose. The blower door presses a switch that cuts power when the door is off or loose. And the float switch in the drain pan shuts the system down, blower included, when condensate water backs up.
If the blower is running but you feel little or no air, look for a clogged filter, blocked return grilles or a coil covered in ice. A frozen coil acts like a wall in the airflow. See frozen coil if you see frost or ice.
Know your limits
When to call a pro
Stop and call a pro if
- A breaker trips again as soon as you reset it.
- You smell burning, or hear buzzing or arcing from the unit. Turn it off at the breakers and leave it off.
- The coil keeps freezing after you have replaced the filter and opened every vent. That can mean low refrigerant, which only a certified tech can handle.
- The blower motor has an electronics module and no capacitor, and it will not run.
- You are not comfortable working around 240 V wiring with a meter.
FAQ
Common questions
Why is my outdoor unit running but no air comes out of the vents?
The outdoor unit and the indoor blower are powered and switched separately. When the outdoor unit runs and the vents are dead, the indoor blower is not moving air. Start with the blower door, the filter and the run capacitor. Turn the system off until it is fixed, or the coil can freeze.
Why does my air handler blower hum but not spin?
That is the classic sign of a weak run capacitor. The motor gets power but not the starting kick it needs. Test or replace the capacitor first. If a new one does not fix it, look at the blower motor.
Can a clogged drain stop my air handler from blowing?
Yes. The float switch shuts the system off, blower included, when water backs up into the pan. Clear the condensate drain and the system should start again. Never bypass the switch to get it running.
Should I close vents in rooms I do not use?
Usually not. A national laboratory study found that closing registers did not save energy in typical homes with ducts outside the living space. Closing a lot of supply vents raises the pressure in the ducts and cuts the airflow over the coil, which can make it freeze.
Related
Keep going
- SymptomAir handler coil frozen: ice on the evaporator coil or linesThe indoor coil has iced over, so little or no cool air reaches the vents. Turn the system off or to fan only and let it thaw. Then check the filter, the return grilles and the blower. If it keeps freezing, low refrigerant is a job for a certified pro.Open guide
- SymptomWater in the air handler drain pan: pan full or system shut offWater is backing up in the drain pan under the coil, or in the pan under the unit, and the system may have shut itself off. A clogged condensate drain is the usual cause. A stuck float switch, a coil that froze and melted, or a cracked pan are the others.Open guide
- Air handler partBlower motor run capacitorFor heat pump and central air handlers with a PSC blower motor, including units with electric heat strips. The run capacitor helps the blower motor start and run. A weak one leaves the blower humming, slow or dead. Air handlers with an ECM motor have no capacitor.Open guide
- Air handler partAir filterFor heat pump and central air handlers, including units with electric heat strips. The filter cleans the air before it reaches the blower and coil. A clogged one chokes airflow, which can freeze the coil in summer and trip the heat strips in winter. Check it monthly.Open guide
- Air handler partBlower motor and wheelFor heat pump and central air handlers, including units with electric heat strips. The blower motor spins a squirrel-cage wheel that pulls air through the filter and coil and pushes it into the ducts. A dirty wheel chokes airflow, and a worn motor hums, squeals or stops.Open guide
- Air handler partFloat switchFor heat pump and central air handlers, including units with electric heat strips. The float switch sits on the drain pan or the drain line. When water rises, the float lifts and cuts the low-voltage control circuit so the system shuts off before the pan overflows.Open guide
- Air handler partCondensate drain pan and lineFor heat pump and central air handlers, including units with electric heat strips. In cooling, the coil wrings water out of the air into a drain pan, and a pipe with a trap carries it away. When slime or debris blocks that pipe, the pan fills and a float switch shuts the system off.Open guide
- Air handler partControl boardThe control board in an air handler takes the thermostat's signals and switches the blower and the electric heat. A blown fuse or a burned relay on it can stop the fan, the heat, or the whole system.Open guide
Get the next fix before it breaks
A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.
We send it with Kit. Privacy