Gas dryer valve coils: what they do and when to call a pro
Gas dryers only. The coils open the gas valve. When the igniter glows, goes out and nothing lights, they are a top suspect, and the fix belongs to a pro.
- Who fixes it
- A licensed pro
- Typical pro cost
- $115–$340
- Typical installed cost, part included. Varies by region
The coils mount on the gas valve. Testing and replacing them means working on the gas valve, and checking for leaks afterward. That is for a qualified pro only.
What it does
What the valve coils does
The gas valve sits on the gas line inside the dryer, just behind the burner. Two or three small round coils sit on top of it. Each one is an electromagnet that pulls part of the valve open when power reaches it.
When the dryer calls for heat, the first coils open the valve part way while the igniter heats up. When the igniter is hot, the flame sensor switches on the last coil. That one lets gas through to the burner, and the gas lights.
So the coils, the igniter and the flame sensor work as a team. If any one of them fails, the burner does not light.
Why it fails
A coil winding can burn open. Then that part of the valve never opens, and gas never reaches the burner.
A coil can also get weak or intermittent. It may work while the dryer is cold, then fail once it warms up. That is why some dryers heat fine on the first load and not on the second.
The same signs can come from a stuck flame sensor, a weak igniter, a closed gas shutoff or low gas supply. A pro confirms which part it is before replacing anything.
Symptoms
Signs the valve coils is failing
Igniter glows, goes out, no flame
This is the classic sign. The igniter glows bright orange for up to a minute or two, then goes dark, and the gas never lights. It may try again later with the same result.
Full diagnosisFirst load dries, second one does not
The dryer heats fine when it starts cold. After a while the burner stops relighting, and the clothes come out damp.
Full diagnosisLights, then keeps going out
The burner lights, goes out, and relights over and over. Weak coils are one cause. A blocked vent is another, so check the vent first.
Full diagnosis
Safety first
Stay safe until it is fixed
- 1
Smell gas? Leave first
Do not light anything, touch electrical switches or use a phone inside. Leave right away and call your gas supplier from outside or a neighbor's phone. If you cannot reach them, call the fire department.
- 2
CO alarm going off? Get out
Get everyone, pets included, into fresh air and call 911 from outside. Do not go back in until responders say it is safe.
- 3
Leave it off until it is checked
If you suspect the gas valve or its coils, unplug the dryer and close the gas shutoff behind it. Leave it off until a pro has looked. Do not open, tap on or adjust the valve.
What a pro does
What to expect from the service call
- Confirm the basics first: the gas shutoff is open, gas reaches the dryer, and the igniter and flame sensor check out.
- Watch a heat cycle and check whether each coil gets power at the right moment, and whether the valve responds.
- Check the coils against the values in the dryer's service data, and look at the valve itself.
- If a coil or the valve is bad, shut off the gas and replace the faulty part with the one listed for the model.
- Check the gas connections for leaks with a leak detection solution, then run several heat cycles to confirm the burner lights and stays lit.
Know your limits
When to call a pro
Stop and call a pro if
- You smell gas at any point. Leave the house and call your gas supplier from outside.
- The igniter glows, then goes out, and the gas never lights, and the gas shutoff is open.
- The dryer heats on the first load but stops lighting once it is warm.
- You have already replaced the igniter or flame sensor and the burner still does not light.
- Anyone suggests swapping the coils or working on the gas valve yourself. On this site we treat that as pro work.
FAQ
Gas valve coils questions
Can I replace gas valve coils myself?
We do not cover it. The coils mount on the gas valve, and any work there should end with a leak check and a test of the burner. We leave that to a qualified pro.
You can safely check the DIY parts first: the igniter, the flame sensor and the thermal fuse.
How do I know it is the coils and not the flame sensor?
Time the glow. An igniter that glows for a minute or two and then goes out with no flame points to the coils. One that glows on and on without lighting points to the flame sensor.
The signs overlap, which is why a pro confirms before replacing parts.
What does a coil replacement cost?
Typically about $115 to $340 installed, part included. Prices vary a lot by region and model.
Related
Keep going
- SymptomDryer runs but won't heatThe drum tumbles but the air stays cold. On an electric dryer, start with the breaker and the thermal fuse. On a gas dryer, start with the gas shutoff and watch the igniter.Open guide
- SymptomDryer takes too long to dryLoads need two cycles, or come out damp. On gas and electric dryers alike, the usual cause is restricted airflow: a clogged lint screen, a blocked vent or a crushed duct. Load size matters too.Open guide
- Dryer partGas dryer igniterGas dryers only. The igniter is a small ceramic element that glows hot enough to light the gas. When it fails, the drum turns but the dryer never heats. You can test it with a meter and, on many dryers, swap it without touching any gas fittings.Open guide
- Dryer partGas dryer flame sensorGas dryers only. The flame sensor is a small heat-sensing switch on the side of the burner. It tells the gas valve when the igniter is hot enough. A bad one can stop the dryer heating, or make it heat for a few minutes and then go cold.Open guide
- Dryer partBurner assemblyGas dryers only. The burner assembly is the tube where gas mixes with air and burns, plus the small orifice that meters the gas. The igniter and flame sensor mount on it. Burner problems are uncommon, and any work on it is for a qualified pro.Open guide