Gas dryer flame sensor test and replacement
Gas dryers only. This little heat switch costs little, tests in a minute, and comes off with two wires and one screw.
- Difficulty
- Easy
- Time
- 20–45 min
- Typical part cost
- $10–$40Pro: $75–$250
- Tools
- 4See the list
Two push-on wires and one screw, on the outside of the burner. You never open a gas fitting.
What it does
What the flame sensor does
The flame sensor, also called a radiant flame sensor or flame detector, is a small round switch on a bracket, mounted on the side of the burner housing. It has two wire terminals.
When it is cold, its contacts are closed. That lets the igniter heat up. When it feels the strong radiant heat of the glowing igniter, its contacts open. That switches the gas valve fully on, and the gas lights.
While the burner runs, the heat of the flame keeps the contacts open. When the burner shuts off and cools, the contacts close again, ready for the next cycle.
Why it fails
It can stick open. Then the igniter never gets power, so there is no glow and no heat.
It can stick closed. Then the igniter glows and glows, but the sensor never signals the gas valve to let gas through, so the burner never lights.
It can also get slow or weak. The burner lights, then goes out, and the dryer heats for a few minutes, goes cold, and tries again.
Symptoms
Signs of a bad flame sensor
Igniter glows, never lights
The igniter glows bright orange and keeps glowing, but the burner never lights. A sensor stuck closed is one possible reason.
Full diagnosisNo glow at all
The drum turns, but the igniter never glows. A sensor stuck open is one cause. A dead igniter or a blown thermal fuse are others.
Full diagnosisHeats, then goes cold
The dryer heats for a few minutes, goes cold, then tries again. Loads take far longer than they should.
Full diagnosis
How to test it
Test the flame sensor before you buy
- Unplug the dryer, close the gas shutoff and let the burner area cool fully.
- Pull both wires off the sensor terminals. Note which wire goes where first.
- Touch one probe to each terminal.
A good sensor at room temperature typically reads
Near 0 Ω (continuity)
Typical range. Check your part label or manual for the exact spec. If it reads fine but the igniter glows and glows with no flame, the sensor may be stuck closed. The [gas valve coils](/dryer/gas-valve-coils) cause similar signs, so a pro may need to confirm.
- Good
- Continuity means the sensor is not stuck open. It can still be stuck closed or slow, which a cold test cannot show.
- Bad
- OL or no continuity means the sensor is stuck open. Replace it.
Safety first
Before you touch anything
- 1
Unplug the dryer
Pull the dryer's plug from the wall before you remove any panel. Turning the dial to off is not enough.
- 2
Close the gas shutoff
The shutoff is on the gas line behind the dryer. Turn the handle a quarter turn so it sits crosswise to the pipe. You will not open any gas fittings in this job. This is a second layer of safety.
- 3
Let it cool
The sensor sits right on the burner. If the dryer just ran, wait until the burner area is cool to the touch.
Wait about 15 min
Tools you'll need
Grab these first
Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works
- Multi-bit screwdriverPhillips, flat, squareThe access panel and the sensor screw are usually Phillips or 1/4 in. hex.Typically $10–$25Shop this tool
- Nut driver1/4 in. hexOptionalMany sensor mounting screws are 1/4 in. hex heads.Typically $6–$15Shop this tool
- Digital multimeterΩ, V, µF, µAA quick continuity check tells you if the sensor is stuck open.Typically $25–$60Shop this tool
- Needle-nose pliersHelps pull the push-on terminals straight off without bending them.Typically $8–$20Shop this tool
- HeadlampThe burner sits low and deep in the cabinet.Typically $12–$30Shop this tool
- Shop vacuumOptionalClears lint from the burner area while the panel is off.Typically $40–$90Shop this tool
Step by step
How to replace the flame sensor
- 1
Unplug the dryer and close the gas
Pull the dryer far enough from the wall to reach the plug and the gas shutoff. Unplug it.
Turn the gas shutoff handle a quarter turn so it sits crosswise to the pipe.
Careful. If you smell gas at any point, stop. Do not touch switches. Leave the house and call your gas supplier from outside.
- 2
Open up the burner area
Depending on the model, the burner is reached through a lower access panel at the front, below the door, or through the back panel. Remove the screws and set the panel aside.
- 3
Find the flame sensor
Look at the side of the burner housing, near the igniter end. The sensor is a small round switch on a bracket, with two wires on push-on terminals.
Do not confuse it with the gas valve coils. Those sit on the gas valve itself, further back on the gas line, and are not part of this job.
Tip. Take a photo of the wires and the bracket now.
- 4
Pull the two wires
Grip each terminal, not the wire, and pull it straight off. Note which wire went on which terminal.
- 5
Remove the mounting screw
One screw usually holds the sensor to the burner housing. Back it out and lift the sensor away. Keep the screw.
- 6
Match the new sensor
Hold the old and new sensors side by side. The bracket, the mounting hole and the terminals should match.
Buy the sensor listed for your dryer's model number.
Buy the part
Gas dryer flame sensor
Opens AppliancePartsPros in a new tab. Where’s my model number?
What to look for
- Your dryer's model number from the rating plate inside the door. Search by that.
- The same bracket shape and two-terminal layout as the old sensor.
- The part number stamped on the old sensor, if you can read it.
- 7
Mount it and reconnect the wires
Set the new sensor in the same spot on the burner housing and snug the screw. Push each wire back onto its terminal, matching your photo.
Tip. While the panel is off, vacuum any lint you can see around the burner area.
- 8
Refit the panel
Put the access panel back and replace its screws.
- 9
Gas on, power on, and test
Turn the gas shutoff handle back in line with the pipe, then plug the dryer in.
Run a timed heat cycle for a few minutes. The igniter should glow, then go dark as the burner lights. Warm air should come out of the vent.
Careful. Never run the dryer with the sensor wires joined together or bypassed. It is a safety part.
Buy the part
Get the right replacement
Buy the part
Gas dryer flame sensor
Opens AppliancePartsPros in a new tab. Where’s my model number?
What to look for
- Your dryer's model number from the rating plate inside the door. Search by that.
- The same bracket shape and two-terminal layout as the old sensor.
- The part number stamped on the old sensor, if you can read it.
Know your limits
When to call a pro
Stop and call a pro if
- You smell gas at any point. Do not touch any switches. Leave the house and call your gas supplier from outside.
- The igniter glows, goes out, and the gas never lights, even with a good sensor. That points to the gas valve coils, which are pro work.
- A carbon monoxide alarm goes off. Get everyone outside and call 911 or the fire department from outside.
- You see scorch marks, melted wires or flame outside the burner.
- Reaching the sensor means loosening the burner or any gas connection.
FAQ
Gas dryer flame sensor questions
Is a dryer flame sensor the same as a furnace flame sensor?
No. A furnace flame sensor is a metal rod that sits in the flame and is often cleaned. A dryer flame sensor is a small heat switch on the burner housing. You cannot clean it back to life. You test it and replace it.
My sensor has continuity. Can it still be bad?
Yes. A cold test only proves it is not stuck open. A sensor that is stuck closed, or slow to open, also reads fine cold. If the igniter glows for a long time and never lights the gas, the sensor is a strong suspect even with a good reading.
Flame sensor or gas valve coils?
Time the glow. An igniter that glows on and on with no flame points to the flame sensor. One that glows for a minute or two, then goes out with no flame, points to the gas valve coils.
The signs overlap, so test the sensor first. It is the cheaper part and a DIY job. The coils are pro work.
Could the vent cause these symptoms?
It can. Service guides list a blocked exhaust or a stuck vent hood flap as a cause of a burner that lights and keeps going out. Check the exhaust vent before you buy parts.
Related
Keep going
- SymptomDryer runs but won't heatThe drum tumbles but the air stays cold. On an electric dryer, start with the breaker and the thermal fuse. On a gas dryer, start with the gas shutoff and watch the igniter.Open guide
- SymptomDryer takes too long to dryLoads need two cycles, or come out damp. On gas and electric dryers alike, the usual cause is restricted airflow: a clogged lint screen, a blocked vent or a crushed duct. Load size matters too.Open guide
- SymptomDryer shuts off earlyThe cycle ends, or the dryer stops mid-cycle, and the clothes are still damp. On gas and electric dryers, the usual causes are a blocked vent making it overheat, a coated moisture sensor, or a door that will not stay shut.Open guide
- Dryer partGas dryer igniterGas dryers only. The igniter is a small ceramic element that glows hot enough to light the gas. When it fails, the drum turns but the dryer never heats. You can test it with a meter and, on many dryers, swap it without touching any gas fittings.Open guide
- Dryer partGas valve coilsGas dryers only. The gas valve coils are small electric windings that open the dryer's gas valve. A classic sign of failing coils is an igniter that glows, then goes out, with no flame. Because they sit on the gas valve, testing and replacing them is pro work.Open guide
- Dryer partThermal fuseThe thermal fuse is a one-time safety fuse that blows when the dryer overheats. Gas and electric dryers both have one. A blown fuse is a warning about airflow, so clean the vent before you replace it.Open guide
- Dryer partExhaust vent and ductThe exhaust duct carries hot, damp air and lint from the back of the dryer to a hood outside. When lint packs into it, drying slows and the dryer runs hot. Gas and electric dryers both need it cleaned about once a year.Open guide