How to clear a heat pump water heater condensate drain
Water around a heat pump water heater is not always a leaking tank. It can be a clogged condensate drain, and clearing that is a short job with a wet/dry vac.
- Difficulty
- Easy
- Time
- 20 min–1 hr
- Typical part cost
- $0Pro: $100–$250
- Tools
- 3See the list
No parts, just a wet/dry vac and some water. The fiddly part is getting the line off its fitting without spilling what is in it.
What it does
What the condensate drain does
As the fan pulls room air across the cold evaporator coil, moisture in the air condenses on the coil, the same way a cold glass sweats. It drips into a pan under the coil. Depending on humidity and how long the heat pump runs, that can be a quart or two a day.
Fittings on the heat pump section carry the water out. Most units have a primary drain port and a second, overflow port. A line runs from the primary port to a floor drain, a sink, or a condensate pump.
Many units watch the drain. If it backs up, the heat pump stops and the display shows a drain fault with an alarm. Most keep making hot water on the backup elements until you clear it.
Why it fails
Dust, algae and slime grow in the drain pan and the line and slowly block them. This is the usual cause.
A line that is not sloped downhill the whole way lets water sit in the sags, where gunk settles.
If both the primary and the overflow lines block, water has nowhere to go and runs out of the plastic shroud and down the outside of the heater.
Symptoms
Signs of a bad condensate drain
Water running down the outside
Water on the jacket or dripping from the plastic shroud at the top means the drain lines may be blocked. Deal with it right away.
Full diagnosisDrain alarm or fault code
Many units stop the heat pump, show a drain fault on the display and beep when the condensate backs up. Check your manual's code list.
Standing water in the pan below
Water sitting in the metal drain pan under the heater can be a clogged condensate line, not a leaking tank. Check the drain before you worry about the tank.
Full diagnosis
How to test it
Test the condensate drain before you buy
- Find where the water is coming from. Wipe the jacket dry and watch it for a while with the heat pump running.
- Look at the end of the condensate line at the floor drain, sink or pump.
Water from the top of the tank's side, near the relief valve, may be the [T&P relief valve](/water-heater/tp-relief-valve) instead. Water at the bottom valve may be the [drain valve](/water-heater/drain-valve).
- Good
- The line drips at its end while the heat pump runs, and the water outside the unit is coming from somewhere else. See the [water heater leaking guide](/water-heater/symptoms/leaking).
- Bad
- The line's end is dry while water spills from the shroud or the fittings. The drain is blocked. Clear it with the steps below.
Safety first
Before you touch anything
- 1
Power off
Turn off the water heater's breaker, or unplug it if it plugs into a wall outlet, before you work around the unit with water. A heater with a blocked drain keeps heating on its elements, so the power is still in use.
- 2
Have a pan ready
The line and the pan inside the unit can be full of water. Set a shallow pan and towels under the fitting before you take the line off.
Tools you'll need
Grab these first
Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works
- Shop vacuumSucks the clog out of the line from its open end. The fastest way to clear it.Typically $40–$90Shop this tool
- Shallow pan and towelsCatches the water that runs out when the line comes off the fitting.Typically $5–$15Shop this tool
- Bucket5 galHolds water for flushing the line, and catches it at the far end.Typically $4–$10Shop this tool
- Pipe cleanersOptionalClears gunk out of the small drain port and fittings without scratching them.Typically $3–$8Shop this tool
- HeadlampOptionalLets you see into the ports and follow the line along the wall.Typically $12–$30Shop this tool
Step by step
How to clean the condensate drain
- 1
Turn off the power
Turn off the water heater's breaker at the main panel. It is usually a double breaker labeled water heater. If your heater plugs into a wall outlet, unplug it instead.
- 2
Find the drain fittings and the line
Find the condensate fittings on the heat pump section. Most units have a primary port, with the drain line on it, and an overflow port. Some have two hoses on the back.
Follow the line to where it ends: a floor drain, a sink, or a small condensate pump.
- 3
Take the line off the fitting
Set the shallow pan and towels under the fitting.
Disconnect the drain line from the primary fitting, the way it is attached on your unit. Let the trapped water run into the pan.
- 4
Clear the ports
Look into the drain port and the overflow port. Clear any debris or slime you can reach. A pipe cleaner works well.
- 5
Vacuum and flush the line
Hold a wet/dry vac hose tight over the far end of the line and run it briefly. That often pulls the clog out.
Then pour water slowly into the end you took off the unit and check that it runs freely out of the far end.
Tip. Some guides suggest a cup of bleach down the line once a year to kill algae. Check your manual first, since not every maker allows it.
- 6
Check the route
Walk the line from the unit to the drain. It should run downhill the whole way, with no sags and no kinks. Manuals call for a slope of at least 1/8 in. per foot.
Water should flow freely out of the end. How the end meets the drain, including any trap or air gap, depends on your manual and local code, so leave a permanent setup as it was installed.
Make sure the condensate does not run into the water heater's own drain pan. Manuals say not to do that.
Careful. Cracked tubing or a broken fitting? Replace it with the same size before you reconnect. A condensate pump that does not run is a separate fix.
Buy the part
Heat pump condensate drain
Opens Amazon in a new tab. Where’s my model number?
What to look for
- The same size as your drain port. Many units use a 3/4 in. threaded primary port.
- For an overflow port, the size your manual gives. Some use a smaller clear tube.
- If there is no drain lower than the heater, a condensate pump. Many have an overflow safety switch.
- 7
Reconnect the line
Put the drain line back on the primary fitting, snug and straight. Reattach anything else you took off.
- 8
Power on and watch it drain
Turn the breaker back on, or plug it back in. If the display shows a drain alarm, clear it as your manual shows.
Let the heat pump run for a while. You should see drips at the end of the line, and the outside of the unit should stay dry.
Buy the part
Get the right replacement
Buy the part
Heat pump condensate drain
Opens Amazon in a new tab. Where’s my model number?
What to look for
- The same size as your drain port. Many units use a 3/4 in. threaded primary port.
- For an overflow port, the size your manual gives. Some use a smaller clear tube.
- If there is no drain lower than the heater, a condensate pump. Many have an overflow safety switch.
Know your limits
When to call a pro
Stop and call a pro if
- The line clogs again within weeks of a cleaning.
- There is no drain the line can run downhill to, and it needs a condensate pump or a new route.
- Water keeps coming from inside the shroud even with a clear drain. The pan or a fitting inside the unit may be cracked.
- Water is coming from the tank itself, not the condensate. A leaking tank usually means a new heater.
FAQ
Heat pump condensate drain questions
Is it normal for a heat pump water heater to make water?
Yes. The coil pulls moisture out of the air, the way an air conditioner does. Depending on humidity and how long the heat pump runs, it can be about one to two quarts a day. The drain line carries it away.
Will I still have hot water with a clogged drain?
Usually. Many units stop the heat pump and keep heating with the backup elements until the drain is clear. That uses more electricity, so clear it soon.
How often should I clean the condensate drain?
Once a year is a good habit, and one maker suggests cleaning the condensate pan after the first six months. Check it any time you clean the air filter.
Can I run the condensate line into the water heater's drain pan?
No. Manuals say not to drain condensate into the water heater's drain pan. Run it downhill to a floor drain, a sink or a condensate pump, and follow your manual and local code for how it connects there.
Related
Keep going
- SymptomHeat pump water heater leaking condensateHeat pump water heaters only. Water around the base, dripping down the side, or a condensate alarm on the display. Usually the condensate drain line is clogged, kinked or not sloped. Rule out the tank's own valves and fittings too.Open guide
- SymptomWater heater leakingWater on the floor or dripping down the tank. Shut off the power or gas and the cold supply, dry everything, then trace the water to its source: a valve, a fitting, an element gasket, or the tank itself.Open guide
- Water heater partHeat pump air filterHeat pump (hybrid) water heaters only. A washable filter cleans the room air before the fan pulls it across the evaporator coil. When it clogs, the heat pump works harder, the filter light comes on, and many units fall back to the electric elements.Open guide
- Water heater partTemperature and pressure relief valveThe T&P relief valve opens to let water out if the tank gets too hot or the pressure gets too high. Gas and electric heaters both have one. Test it once a year by lifting its lever.Open guide
- Water heater partDrain valve and tank flushThe drain valve near the bottom of the tank lets you empty it and flush out sediment. Manufacturers suggest flushing gas and electric tanks about once a year, more often with hard water.Open guide
Get the next fix before it breaks
A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.
We send it with Kit. Privacy
