WhatsBusted
Symptom

Heat pump water heater leaking water from the top?

A heat pump water heater makes water as it runs, the same way an air conditioner does. A puddle is often just that water going the wrong way, and the drain is usually the fix.

Check these first

Five-minute checks, no tools

  • Power off first

    Turn off the heater's breaker before you work on the drain, especially if water is near the wiring or the controls.

  • Follow the drain line

    Trace the condensate tube or pipe from the unit to where it ends. Look for kinks, sags, a spot where it runs uphill, or a tube that has slipped off its fitting.

  • Check for a clog

    Look at the drain fittings and the end of the line for slime or debris. Water standing in the line means it is blocked. See the [condensate drain guide](/water-heater/heat-pump-condensate-drain).

  • Condensate pump working

    If the line runs to a small pump, check that it is plugged in and runs when its tank fills. A pump that has stopped lets water back up into the heater.

  • Rule out the tank

    Dry the relief valve, its pipe, the drain valve and the water connections, then watch. Water there is a tank leak, not condensate. See [water heater leaking](/water-heater/symptoms/leaking).

Likely causes

Ranked by how often they are the problem

  1. 1

    Clogged condensate drain

    DIY fix

    Water spills from the heat pump housing, or the display shows a condensate alarm. Dirt, slime or algae has blocked the fitting or the line, so the water backs up. Clearing the fittings and flushing the line is the fix.

  2. 2

    Drain line kinked, sagging or loose

    DIY fix

    The line has a kink, runs uphill somewhere, or has slipped off its fitting. Condensate drains by gravity, so the line must slope down the whole way. Reseat it and support it so it falls to the drain.

  3. 3

    Condensate pump failed

    DIY fix

    The line runs to a pump, and the pump's tank is full but it does not run. Check that it is plugged in and the outlet has power. A pump that still will not run needs replacing.

  4. 4

    Relief valve or tank fitting leak

    DIY fix

    Water comes from the relief valve, its discharge pipe, the drain valve or a pipe connection, even when the heat pump is not running. That is the tank's plumbing, not condensate. Never cap or plug the relief valve.

  5. 5

    Leaking tank

    Call a pro

    The condensate line is clear and every fitting is dry, but water still pools under the tank. The tank itself has failed. It cannot be repaired, so the heater needs replacing.

What's happening

What your water heater is doing

The heat pump cools and dries the air it pulls across its coil, so moisture condenses on the coil the way it does on a cold glass. That water collects in a pan under the coil and leaves through drain fittings on the heat pump housing.

Most units have two drain fittings: a primary drain and an overflow, or secondary, drain. Each one runs through a tube or pipe to a floor drain, a sink or a condensate pump. The line has to slope down all the way, and it must not be capped.

When the line clogs with dirt, slime or algae, or kinks, the pan fills and water spills over, or a sensor sees it and the display shows a condensate alarm. Water in a pan under the heater can be condensate overflow or a tank leak, so check both.

Not every puddle is condensate. The relief valve, the drain valve and the pipe connections can leak on a heat pump heater just as on any tank. Condensate shows up while the heat pump runs, not all the time.

Know your limits

When to call a pro

Stop and call a pro if

  • The tank itself is leaking. Plan on a replacement.
  • The relief valve keeps releasing water. Do not cap or plug it.
  • The condensate alarm keeps coming back with a clear drain line. The sensor may be faulty.
  • The heater has no proper place to drain and needs a condensate pump or a new drain run.

FAQ

Common questions

Is it normal for a heat pump water heater to make water?

Yes. It cools and dries the air it uses, so water condenses on the coil and drains away.

Can I cap the overflow condensate fitting?

Not unless your manual says so. Many manuals say not to cap or plug the condensate drain, because water that cannot drain can damage the heater. Follow your installation manual for both fittings.

How do I unclog a heat pump water heater condensate line?

Turn off the power, then clear the drain fittings and flush the line until water runs freely to the drain. The condensate drain guide walks through it.

Related

Keep going

Get the next fix before it breaks

A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.

We send it with Kit. Privacy