Heat pump water heater fan motor: test and replace

A hum from the top of a heat pump water heater is normal. A knock, a grind or a fan fault code is not, and the fan assembly comes out of the top after a few screws.

Difficulty
Moderate
Time
45 min–1.5 hr
Typical part cost
$200–$700Pro: $200–$700

Only screws and one plug, but it is a 240 V appliance with the fan sitting close to the refrigerant tubing. You need to verify the power is dead and keep your hands off the coil and tubes.

What it does

What the evaporator fan does

The fan sits in the top of the unit, above or beside the evaporator coil. It pulls room air in through the filter and across the coil, and blows the cooled air back out.

It runs while the heat pump is heating water, not all the time. On some models it keeps running for a while after the compressor stops. A steady hum, like a microwave's vent fan, is normal.

Why it fails

The motor itself can fail, or its connector can work loose. Many units show a fan fault code when the fan does not run as it should.

A blade that rubs, sits off center or has come loose makes knocking and scraping noises.

A clogged air filter makes everything work harder. Clean it first whenever the fan or the heat pump acts up.

Symptoms

Signs of a bad evaporator fan

  • Knocking or grinding from the top

    A soft hum is normal. Knocking, grinding or scraping from the top of the unit is not, and the fan is the first thing to check.

    Full diagnosis
  • Fan fault code

    Many units show a fan fault on the display when the fan is not running. Look the code up in your manual.

  • Heat pump runs on elements only

    With the fan stopped the heat pump cannot take heat from the air. Depending on the model it stops with a fault, or the backup elements carry the load and the savings are gone.

    Full diagnosis

How to test it

Test the evaporator fan before you buy

1. Listen while it heatsNo meter needed
  1. Run hot water at a tap for a while so the heater calls for heat.
  2. Stand by the unit and listen at the top once the heat pump starts.

Many units wait a few minutes after the power comes on before the heat pump starts, up to about 5 minutes on some models.

Good
A steady hum, and cool air coming out. The fan is running. Look at the filter or the drain if something else is wrong.
Bad
Silence while the display says it is heating, a fan fault code, or a knock or grind. Turn the power off and do the spin check.
2. Spin the bladeNo meter needed
  1. Turn the breaker off and take off the top cover (steps 1 to 3 below).
  2. Turn the fan blade slowly by hand and watch it go around.
Good
It turns freely and smoothly, without touching the ring or any wires.
Bad
It is stiff, grinds, wobbles or rubs. Replace the fan assembly. If it only rubs on a loose wire, move the wire clear and spin it again.

Safety first

Before you touch anything

  1. 1

    Power off, then verify

    Turn off the water heater's breaker, usually a double breaker. If your heater plugs into a wall outlet, unplug it. With the top cover off, hold a voltage tester to the wiring before you touch anything, after checking the tester on a working outlet. The fan can start without warning if the power is on.

  2. 2

    Hands off the coil and tubing

    The evaporator coil and the copper refrigerant tubes sit next to the fan. Do not bend, pry on or lean on them. A damaged tube is a sealed-system repair for a certified pro.

Tools you'll need

Grab these first

Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works

See the full repair tool kit

Step by step

How to replace the evaporator fan

  1. 1

    Turn off the power

    Turn off the water heater's breaker at the main panel. It is usually a double breaker labeled water heater. If there is a disconnect switch by the heater, turn that off too. If your heater plugs into a wall outlet, unplug it.

    Careful. The fan can start without warning while the power is on. The breaker stays off until the cover is back on.

  2. 2

    Take off the top cover

    Remove the screws around the top cover. Lift it off and set it aside, or flip it over if the fan is mounted to it. Watch for any wire attached to it.

  3. 3

    Check for power

    Hold the voltage tester to the power wires where they enter the control area. It should stay quiet. If it beeps or lights, stop and find the right breaker.

  4. 4

    Unplug the fan

    Take a photo of the fan cable and how it is routed. Then unplug the fan's connector. Squeeze the locking tab and pull on the plug, not the wires.

  5. 5

    Remove the fan assembly

    Remove the screws around the outside of the fan assembly and lift it straight out.

    Careful. Lift it clear of the coil and the copper tubes. Do not let it drop onto them.

  6. 6

    Match the new fan

    Order the fan assembly by the model and serial number on the heater's rating label. Compare the new one to the old one: the same mounting holes, the same blade and the same connector.

  7. Buy the part

    Heat pump evaporator fan motor

    Opens Amazon in a new tab. Where’s my model number?

    What to look for

    • The part your heater's parts list gives for its model and serial number. Fans differ by brand and model.
    • A complete fan assembly, with the motor, blade and mount together, if your model's part is sold that way.
    • The same connector as the old fan, so it plugs straight in.
  8. 7

    Install the new fan

    Set the new assembly in place and put the screws back. Route the cable the way it was in your photo and plug it in until it clicks.

    Before any power goes on, spin the blade by hand. It should turn freely and touch nothing.

  9. 8

    Refit the top cover

    Set the top cover back on and put all its screws back.

  10. 9

    Power on and test it

    Turn the breaker back on, and the disconnect if there is one, or plug it back in.

    Run hot water so the heater calls for heat, then listen. The heat pump may take a few minutes to start. Once it does, you should hear a steady hum and feel cool air coming out.

Buy the part

Get the right replacement

Buy the part

Heat pump evaporator fan motor

Opens Amazon in a new tab. Where’s my model number?

What to look for

  • The part your heater's parts list gives for its model and serial number. Fans differ by brand and model.
  • A complete fan assembly, with the motor, blade and mount together, if your model's part is sold that way.
  • The same connector as the old fan, so it plugs straight in.

Know your limits

When to call a pro

Stop and call a pro if

  • The new fan runs but the knocking or abnormal noise is still there.
  • A new fan still shows a fan fault or does not run. The control board or the wiring may be the problem.
  • You bent or touched a refrigerant tube, or you hear a hiss. Turn the power off and call a certified tech. See the sealed system page.
  • You are not comfortable confirming that the wiring is dead before you touch it.

FAQ

Heat pump evaporator fan motor questions

Is fan noise from a heat pump water heater normal?

A steady hum is. Manufacturers compare it to a microwave's vent fan or the blower on a central air system. The fan only runs while the heat pump is heating, and on some models for a while after. Knocking, grinding or other odd noises are not normal.

Can I still get hot water with a dead fan?

On many units, yes. The backup heating elements can heat the tank in electric mode, but it uses a lot more electricity. Some units stop with a fault instead. Check your manual for how to switch modes.

Do I need to drain the tank to replace the fan?

Usually not. The fan is in the top section, away from the water, so the power is what has to be off. Check your manual's service steps, since some makers list a fuller shutdown.

Could a dirty filter be the real problem?

It is worth checking first. A clogged filter makes the heat pump work harder and can trigger alerts. Clean the air filter before you buy a fan.