Heat pump water heater fan motor: test and replace
A hum from the top of a heat pump water heater is normal. A knock, a grind or a fan fault code is not, and the fan assembly comes out of the top after a few screws.
- Difficulty
- Moderate
- Time
- 45 min–1.5 hr
- Typical part cost
- $200–$700Pro: $200–$700
- Tools
- 3See the list
Only screws and one plug, but it is a 240 V appliance with the fan sitting close to the refrigerant tubing. You need to verify the power is dead and keep your hands off the coil and tubes.
What it does
What the evaporator fan does
The fan sits in the top of the unit, above or beside the evaporator coil. It pulls room air in through the filter and across the coil, and blows the cooled air back out.
It runs while the heat pump is heating water, not all the time. On some models it keeps running for a while after the compressor stops. A steady hum, like a microwave's vent fan, is normal.
Why it fails
The motor itself can fail, or its connector can work loose. Many units show a fan fault code when the fan does not run as it should.
A blade that rubs, sits off center or has come loose makes knocking and scraping noises.
A clogged air filter makes everything work harder. Clean it first whenever the fan or the heat pump acts up.
Symptoms
Signs of a bad evaporator fan
Knocking or grinding from the top
A soft hum is normal. Knocking, grinding or scraping from the top of the unit is not, and the fan is the first thing to check.
Full diagnosisFan fault code
Many units show a fan fault on the display when the fan is not running. Look the code up in your manual.
Heat pump runs on elements only
With the fan stopped the heat pump cannot take heat from the air. Depending on the model it stops with a fault, or the backup elements carry the load and the savings are gone.
Full diagnosis
How to test it
Test the evaporator fan before you buy
- Run hot water at a tap for a while so the heater calls for heat.
- Stand by the unit and listen at the top once the heat pump starts.
Many units wait a few minutes after the power comes on before the heat pump starts, up to about 5 minutes on some models.
- Good
- A steady hum, and cool air coming out. The fan is running. Look at the filter or the drain if something else is wrong.
- Bad
- Silence while the display says it is heating, a fan fault code, or a knock or grind. Turn the power off and do the spin check.
- Turn the breaker off and take off the top cover (steps 1 to 3 below).
- Turn the fan blade slowly by hand and watch it go around.
- Good
- It turns freely and smoothly, without touching the ring or any wires.
- Bad
- It is stiff, grinds, wobbles or rubs. Replace the fan assembly. If it only rubs on a loose wire, move the wire clear and spin it again.
Safety first
Before you touch anything
- 1
Power off, then verify
Turn off the water heater's breaker, usually a double breaker. If your heater plugs into a wall outlet, unplug it. With the top cover off, hold a voltage tester to the wiring before you touch anything, after checking the tester on a working outlet. The fan can start without warning if the power is on.
- 2
Hands off the coil and tubing
The evaporator coil and the copper refrigerant tubes sit next to the fan. Do not bend, pry on or lean on them. A damaged tube is a sealed-system repair for a certified pro.
Tools you'll need
Grab these first
Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works
- Non-contact voltage testerPen styleConfirms the power is dead at the wiring before you touch anything. Most units run on 240 V, and the fan can start without warning.Typically $15–$30Shop this tool
- Multi-bit screwdriverPhillips, flat, squareTakes out the top cover screws and the screws that hold the fan assembly.Typically $10–$25Shop this tool
- Painter's tape and markerLabel the fan cable and its route before you unplug it.Typically $5–$12Shop this tool
- Work glovesOptionalProtects your hands while you work in the top section.Typically $8–$20Shop this tool
- HeadlampOptionalThe top section is dark with the cover only partly off.Typically $12–$30Shop this tool
Step by step
How to replace the evaporator fan
- 1
Turn off the power
Turn off the water heater's breaker at the main panel. It is usually a double breaker labeled water heater. If there is a disconnect switch by the heater, turn that off too. If your heater plugs into a wall outlet, unplug it.
Careful. The fan can start without warning while the power is on. The breaker stays off until the cover is back on.
- 2
Take off the top cover
Remove the screws around the top cover. Lift it off and set it aside, or flip it over if the fan is mounted to it. Watch for any wire attached to it.
- 3
Check for power
Hold the voltage tester to the power wires where they enter the control area. It should stay quiet. If it beeps or lights, stop and find the right breaker.
- 4
Unplug the fan
Take a photo of the fan cable and how it is routed. Then unplug the fan's connector. Squeeze the locking tab and pull on the plug, not the wires.
- 5
Remove the fan assembly
Remove the screws around the outside of the fan assembly and lift it straight out.
Careful. Lift it clear of the coil and the copper tubes. Do not let it drop onto them.
- 6
Match the new fan
Order the fan assembly by the model and serial number on the heater's rating label. Compare the new one to the old one: the same mounting holes, the same blade and the same connector.
Buy the part
Heat pump evaporator fan motor
Opens Amazon in a new tab. Where’s my model number?
What to look for
- The part your heater's parts list gives for its model and serial number. Fans differ by brand and model.
- A complete fan assembly, with the motor, blade and mount together, if your model's part is sold that way.
- The same connector as the old fan, so it plugs straight in.
- 7
Install the new fan
Set the new assembly in place and put the screws back. Route the cable the way it was in your photo and plug it in until it clicks.
Before any power goes on, spin the blade by hand. It should turn freely and touch nothing.
- 8
Refit the top cover
Set the top cover back on and put all its screws back.
- 9
Power on and test it
Turn the breaker back on, and the disconnect if there is one, or plug it back in.
Run hot water so the heater calls for heat, then listen. The heat pump may take a few minutes to start. Once it does, you should hear a steady hum and feel cool air coming out.
Buy the part
Get the right replacement
Buy the part
Heat pump evaporator fan motor
Opens Amazon in a new tab. Where’s my model number?
What to look for
- The part your heater's parts list gives for its model and serial number. Fans differ by brand and model.
- A complete fan assembly, with the motor, blade and mount together, if your model's part is sold that way.
- The same connector as the old fan, so it plugs straight in.
Know your limits
When to call a pro
Stop and call a pro if
- The new fan runs but the knocking or abnormal noise is still there.
- A new fan still shows a fan fault or does not run. The control board or the wiring may be the problem.
- You bent or touched a refrigerant tube, or you hear a hiss. Turn the power off and call a certified tech. See the sealed system page.
- You are not comfortable confirming that the wiring is dead before you touch it.
FAQ
Heat pump evaporator fan motor questions
Is fan noise from a heat pump water heater normal?
A steady hum is. Manufacturers compare it to a microwave's vent fan or the blower on a central air system. The fan only runs while the heat pump is heating, and on some models for a while after. Knocking, grinding or other odd noises are not normal.
Can I still get hot water with a dead fan?
On many units, yes. The backup heating elements can heat the tank in electric mode, but it uses a lot more electricity. Some units stop with a fault instead. Check your manual for how to switch modes.
Do I need to drain the tank to replace the fan?
Usually not. The fan is in the top section, away from the water, so the power is what has to be off. Check your manual's service steps, since some makers list a fuller shutdown.
Could a dirty filter be the real problem?
It is worth checking first. A clogged filter makes the heat pump work harder and can trigger alerts. Clean the air filter before you buy a fan.
Related
Keep going
- SymptomHeat pump water heater noisy fanHeat pump water heaters only. The fan on top is louder than it used to be, or it rattles, scrapes or knocks. Start with the air filter, then look for something touching the fan and check the unit sits level and solid.Open guide
- SymptomHeat pump water heater slow to recoverHeat pump water heaters only. The hot water runs out and takes a long time to come back. Check the operating mode, the air filter, the room's size and temperature, and the backup heating elements.Open guide
- Water heater partHeat pump air filterHeat pump (hybrid) water heaters only. A washable filter cleans the room air before the fan pulls it across the evaporator coil. When it clogs, the heat pump works harder, the filter light comes on, and many units fall back to the electric elements.Open guide
- Water heater partHeat pump control boardHeat pump (hybrid) water heaters only. The control board runs the whole heater: the compressor, the fan, the backup elements and the display. A failed board can leave the heater dead or stuck on a fault. Most of these heaters run on 240 V, so the power goes off and the wiring is tested dead before you touch it.Open guide
- Water heater partHeating elementElectric water heaters only. Two heating elements, one upper and one lower, heat the water. A burned-out element is the most common reason an electric water heater stops making hot water, and both test and replace the same way.Open guide
Get the next fix before it breaks
A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.
We send it with Kit. Privacy