WhatsBusted
Symptom

Water heater pilot won't stay lit

Gas water heaters only. The pilot is a safety check as much as a flame. When it keeps going out, the heater is usually telling you a sensor or the air supply needs a pro's attention.

Check these first

Five-minute checks, no tools

  • Smell for gas first

    If you smell gas, do not light anything or touch switches. Leave the house and call your gas utility from outside.

  • Gas shutoff open

    The handle on the gas line to the heater should sit in line with the pipe. Crosswise means closed. Check that another gas appliance, like the stove, works.

  • Relight once, by the label

    Follow the lighting instructions on the heater's label exactly, including the wait for gas to clear. If the pilot still will not stay lit, stop and call a pro.

  • Air openings clear

    Look at the air openings around the base of the heater. Keep them free of dust, lint and stored items, and vacuum the outside of them if your manual says to. Never store gasoline, paint or solvents near the heater.

Likely causes

Ranked by how often they are the problem

  1. 1

    Thermocouple

    Call a pro

    The most common cause. The pilot lights, but goes out as soon as you release the control knob, because a worn or loose thermocouple is not holding the gas valve open.

  2. 2

    Dirty or weak pilot

    Call a pro

    A clogged pilot tube or orifice makes a small, weak or wavering flame that does not heat the thermocouple well. Cleaning it means working on the gas parts.

  3. 3

    Blocked air intake or flame arrestor

    Call a pro

    Newer heaters with a sealed burner area take air through a screen at the base. When lint or dust clogs it, the burner starves for air, and a safety switch in the thermocouple shuts the pilot off. A discolored arrestor can mean the heater must be replaced.

  4. 4

    Gas control valve

    Call a pro

    The control's overheat cutoff has tripped, or the valve itself is faulty. If the water got very hot before the pilot went out, suspect this. The control is never repaired or adjusted, only replaced.

  5. 5

    Gas supply problem

    Call a pro

    Low gas pressure, dirt in the line, or air in the line after new gas work. A pro or your gas utility purges and checks the supply.

  6. 6

    Drafts, downdrafts or dripping condensation

    Call a pro

    A strong draft or a venting problem can blow the pilot out. On a tank full of cold water, heavy condensation can drip onto the pilot. Condensation fades as the tank heats. A venting problem needs a pro.

What's happening

What your water heater is doing

A standing pilot is a small flame that burns all the time and lights the main burner when the tank needs heat. Next to it sits a thermocouple, a metal probe that heats up in the pilot flame.

The heat of the pilot makes the thermocouple put out a tiny electric current. That current holds the safety valve in the gas control open. If the pilot goes out, the current stops and the valve shuts off the gas. That is what keeps unburned gas from building up.

So when the pilot will not stay lit, either the flame is not heating the thermocouple well, the thermocouple is worn out, or a safety device is cutting the circuit on purpose. On newer heaters with a sealed combustion chamber, a lint-clogged air intake is a common trigger.

Relighting the pilot exactly as the lighting instructions on the heater's label describe is normal owner operation. Anything past that, from the thermocouple to the gas control, is gas work for a pro.

Know your limits

When to call a pro

Stop and call a pro if

  • You smell gas. Do not touch any switches. Leave the house and call your gas utility from outside.
  • The pilot will not stay lit after you follow the label's lighting instructions once.
  • The flame arrestor or the area under the burner looks scorched or discolored, or flammable vapors may have been near the heater.
  • The gas control got wet, or the water got scalding hot before the pilot went out.
  • Other gas appliances are out too, or gas work was just done. Call your gas utility.

FAQ

Common questions

Why does the pilot go out when I let go of the knob?

While you hold the knob, you are holding the gas open by hand. Once you let go, the thermocouple has to keep it open with the small current it makes in the pilot flame. If it cannot, the gas shuts off and the pilot goes out. A worn thermocouple or a weak pilot flame are the usual reasons.

Can I replace the thermocouple myself?

We do not cover it. The thermocouple connects to the gas control, and a bad connection there can leak gas or stop the safety shutoff from working. On newer heaters it is also part of a sealed burner area. Have a pro or your gas utility do it.

Is it safe to keep relighting the pilot?

Relight it once, following the label exactly, including the wait for any gas to clear. If it goes out again, stop. Repeated tries do not fix the cause, and the safety devices are shutting the gas off for a reason.

What is a flame arrestor?

Many newer gas water heaters have a sealed burner area that takes air in through a fine screen or plate at the base. It stops flames from escaping if flammable vapors get drawn in. Lint and dust can clog it, which starves the burner of air and shuts the pilot off. Cleaning it is a pro job.