Water heater pilot won't stay lit
Gas water heaters only. The pilot is a safety check as much as a flame. When it keeps going out, the heater is usually telling you a sensor or the air supply needs a pro's attention.
Check these first
Five-minute checks, no tools
Smell for gas first
If you smell gas, do not light anything or touch switches. Leave the house and call your gas utility from outside.
Gas shutoff open
The handle on the gas line to the heater should sit in line with the pipe. Crosswise means closed. Check that another gas appliance, like the stove, works.
Relight once, by the label
Follow the lighting instructions on the heater's label exactly, including the wait for gas to clear. If the pilot still will not stay lit, stop and call a pro.
Air openings clear
Look at the air openings around the base of the heater. Keep them free of dust, lint and stored items, and vacuum the outside of them if your manual says to. Never store gasoline, paint or solvents near the heater.
Likely causes
Ranked by how often they are the problem
- 1Call a pro
Thermocouple
The most common cause. The pilot lights, but goes out as soon as you release the control knob, because a worn or loose thermocouple is not holding the gas valve open.
- 2Call a pro
Dirty or weak pilot
A clogged pilot tube or orifice makes a small, weak or wavering flame that does not heat the thermocouple well. Cleaning it means working on the gas parts.
- 3Call a pro
Blocked air intake or flame arrestor
Newer heaters with a sealed burner area take air through a screen at the base. When lint or dust clogs it, the burner starves for air, and a safety switch in the thermocouple shuts the pilot off. A discolored arrestor can mean the heater must be replaced.
- 4Call a pro
Gas control valve
The control's overheat cutoff has tripped, or the valve itself is faulty. If the water got very hot before the pilot went out, suspect this. The control is never repaired or adjusted, only replaced.
- 5Call a pro
Gas supply problem
Low gas pressure, dirt in the line, or air in the line after new gas work. A pro or your gas utility purges and checks the supply.
- 6Call a pro
Drafts, downdrafts or dripping condensation
A strong draft or a venting problem can blow the pilot out. On a tank full of cold water, heavy condensation can drip onto the pilot. Condensation fades as the tank heats. A venting problem needs a pro.
What's happening
What your water heater is doing
A standing pilot is a small flame that burns all the time and lights the main burner when the tank needs heat. Next to it sits a thermocouple, a metal probe that heats up in the pilot flame.
The heat of the pilot makes the thermocouple put out a tiny electric current. That current holds the safety valve in the gas control open. If the pilot goes out, the current stops and the valve shuts off the gas. That is what keeps unburned gas from building up.
So when the pilot will not stay lit, either the flame is not heating the thermocouple well, the thermocouple is worn out, or a safety device is cutting the circuit on purpose. On newer heaters with a sealed combustion chamber, a lint-clogged air intake is a common trigger.
Relighting the pilot exactly as the lighting instructions on the heater's label describe is normal owner operation. Anything past that, from the thermocouple to the gas control, is gas work for a pro.
Know your limits
When to call a pro
Stop and call a pro if
- You smell gas. Do not touch any switches. Leave the house and call your gas utility from outside.
- The pilot will not stay lit after you follow the label's lighting instructions once.
- The flame arrestor or the area under the burner looks scorched or discolored, or flammable vapors may have been near the heater.
- The gas control got wet, or the water got scalding hot before the pilot went out.
- Other gas appliances are out too, or gas work was just done. Call your gas utility.
FAQ
Common questions
Why does the pilot go out when I let go of the knob?
While you hold the knob, you are holding the gas open by hand. Once you let go, the thermocouple has to keep it open with the small current it makes in the pilot flame. If it cannot, the gas shuts off and the pilot goes out. A worn thermocouple or a weak pilot flame are the usual reasons.
Can I replace the thermocouple myself?
We do not cover it. The thermocouple connects to the gas control, and a bad connection there can leak gas or stop the safety shutoff from working. On newer heaters it is also part of a sealed burner area. Have a pro or your gas utility do it.
Is it safe to keep relighting the pilot?
Relight it once, following the label exactly, including the wait for any gas to clear. If it goes out again, stop. Repeated tries do not fix the cause, and the safety devices are shutting the gas off for a reason.
What is a flame arrestor?
Many newer gas water heaters have a sealed burner area that takes air in through a fine screen or plate at the base. It stops flames from escaping if flammable vapors get drawn in. Lint and dust can clog it, which starves the burner of air and shuts the pilot off. Cleaning it is a pro job.
Related
Keep going
- SymptomWater heater not heating: no hot waterEvery hot tap runs cold. On an electric heater it is usually power, a tripped high-limit reset, an element or a thermostat. On a gas heater, start with the gas supply and the pilot.Open guide
- SymptomWater heater smells like rotten eggsA rotten egg smell in the air near a gas appliance can mean a gas leak: leave now and call the gas utility from outside. Sulfur-smelling hot water is a different, harmless problem, usually bacteria reacting with the anode rod.Open guide
- Water heater partThermocoupleGas water heaters only. The thermocouple sits in the pilot flame and tells the gas control the pilot is burning. When it fails, the pilot will not stay lit. On sealed-chamber heaters, replacing it is pro work.Open guide
- Water heater partPilot assemblyGas water heaters only. The pilot assembly makes the small, steady flame that lights the main burner. A dirty or worn pilot will not stay lit. Cleaning or replacing it is pro work on sealed-chamber heaters.Open guide
- Water heater partGas control valveGas water heaters only. The gas control valve is the heater's thermostat and gas valve in one. It decides when gas reaches the burner and shuts it off if something is wrong. Testing or replacing it is pro work.Open guide
- Water heater partBurner assemblyGas water heaters only. The burner sits under the tank and heats the water with a blue flame. Dust and lint upset the flame, which makes soot and carbon monoxide. Burner work is for a pro.Open guide