WhatsBusted
3D model of a sealed system and refrigerant
Call a proAlso called refrigerant leak, freon leak

Refrigerator refrigerant leak and sealed system: when to call a pro

Refrigerators do not use up refrigerant. If it is low, something leaks, and finding and fixing that is a job for an EPA-certified technician.

Who fixes it
A licensed pro
Typical pro cost
$200–$1,250
Typical installed cost. Varies a lot by the fault and region

Licensed work. Finding a leak, repairing tubing and recharging refrigerant need EPA certification, recovery equipment, brazing tools and gauges.

What it does

What the sealed system does

Refrigerant circulates in a closed loop, sealed at the factory. It picks up heat at the evaporator coil in the freezer and gives it off at the condenser coil underneath.

Nothing in the loop is meant to be opened or topped up during the refrigerator's life.

Why it fails

A tube can be punctured or damaged. Refrigerant leaks out slowly or all at once.

Less often, a restriction inside the tubing blocks the flow.

Good news: a refrigerator that will not cool is more often a dirty coil, a stopped fan, a defrost problem or a failed start relay. Rule those out first.

Symptoms

Signs the sealed system is failing

  • Runs all the time, both sections warm

    The compressor and both fans run, the condenser coil is clean, and neither section gets properly cold.

    Full diagnosis
  • Oily spots or a hiss

    Oily residue on the tubing or coil, or a hissing sound after the coil was damaged, points to a leak.

Safety first

Stay safe until it is fixed

  1. 1

    Unplug it if a tube is damaged

    If you punctured or bent a tube, unplug the refrigerator, keep flames and sparks away, ventilate the room and leave the area until any hissing stops. Many newer refrigerators use a flammable refrigerant. Then call a pro.

  2. 2

    Do not open or top it up

    Federal rules prohibit knowingly releasing refrigerant and require an EPA-certified technician to service the sealed system. DIY recharge cans are not a fix for a refrigerator.

What a pro does

What to expect from the service call

  • Confirm the fans, defrost system and coil are all working, so the sealed system is really the problem.
  • Check the system with gauges and find the leak or restriction.
  • Recover any remaining refrigerant, repair or replace the leaking part, and usually replace the filter drier.
  • Pull a deep vacuum and recharge to the exact amount on the rating label, then watch it cool through a few cycles.

Know your limits

When to call a pro

Stop and call a pro if

  • The refrigerator runs nonstop and does not cool, with clean coils and both fans working.
  • You damaged a tube or the coil, or you hear a hiss.
  • You see oily residue on the coil or tubing.
  • Anyone suggests adding refrigerant without finding and fixing the leak.

FAQ

Sealed system and refrigerant questions

Can I recharge my refrigerator myself?

No. The refrigerant loop is sealed, and servicing it takes EPA certification and equipment to recover the refrigerant and pull a vacuum. If the charge is low, there is a leak that has to be fixed first.

How do I know it is not something cheaper?

Rule out the easy parts: clean the condenser coils, check the condenser fan and the evaporator fan, look for an iced-over coil, and listen for a start relay clicking. If all of those check out, call a pro.

I chipped the ice and heard a hiss. What now?

Unplug the refrigerator, open a window and step away until the hiss stops. Move the food to coolers and call a refrigerator technician. The coil or tube will need a sealed-system repair.

Related

Keep going

Get the next fix before it breaks

A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.

We send it with Kit. Privacy