How to flush and descale a tankless water heater
Good news: this is the tankless job you can do yourself. A small pump, two hoses and a bucket of vinegar do the work while you wait, and it is the single best thing you can do for the heater.
- Difficulty
- Easy
- Time
- 1.5 hr–2.5 hr
- Typical part cost
- $10–$50Pro: $150–$350
- Tools
- 5See the list
No parts come off. You close a few valves, hook up two hoses and let a pump run. The care goes into the shutoffs and the order you open things back up.
What it does
What the descaling does
A tankless heater heats water as it rushes through narrow passages: a copper heat exchanger over the burner on a gas unit, or heating chambers with an element in each on an electric one. A flush pumps a descaling solution around those passages to dissolve the mineral scale that builds up inside.
You do it through the isolation valves under the heater. Each valve has a small service port with a cap. Close the main valves and the heater is cut off from your plumbing, so the pump can push solution in through the cold side and out of the hot side, back into the bucket.
Why it fails
Hard water carries calcium and magnesium. When it heats, some of that drops out as scale on the hot surfaces inside the heater. How fast it builds depends on how hard your water is.
Scale narrows the passages and insulates the metal from the water, so the heater has to work harder, flow drops, and the hot water may not get as hot.
Left long enough, scale can damage the heat exchanger. At least one maker says damage from lime build-up is not covered by its warranty.
Symptoms
Signs of a bad descaling
A flush reminder or scale code
Some tankless heaters watch for scale and show a code or a maintenance message when it is time to flush. Look the code up in your manual.
Full diagnosisWeak hot water, strong cold
If the hot water flow has dropped but the cold still runs strong, scale inside the heater is a likely cause. If both are weak, check the inlet screen and the supply first.
Full diagnosisTemperature swings
Mineral buildup is one of the reasons the water runs hot, then cooler, then hot again.
A year since the last flush
Most makers call for a flush about once a year, and sooner with hard water. If you cannot remember the last one, it is due.
How to test it
Test the descaling before you buy
- Open a faucet that is close to the heater all the way on cold and notice how strong the flow is.
- Turn it off, then open it all the way on hot and compare.
If both hot and cold are weak, the problem is upstream of the heater: the supply, a whole-house filter or the heater's inlet screen.
- Good
- Hot and cold run about the same. Scale is not choking the heater yet. Stick to the yearly flush.
- Bad
- The hot water is clearly weaker than the cold. Scale in the heater is the likely reason. Flush it, and clean the inlet screen while you are at it.
Safety first
Before you touch anything
- 1
Power off
Gas units: unplug the heater or turn off its breaker. The on/off button on the controller is not enough. Electric units: turn off every breaker that feeds the heater. Big electric tankless units often have two or more.
- 2
Gas units: close the gas shutoff
Turn the quarter-turn gas shutoff on the line to the heater so the handle sits across the pipe. That is the only gas part you touch. Electric units skip this.
- 3
Let it cool
Water inside a heater that just ran can be very hot. Give it time to cool before you open the service ports.
- 4
Close both isolation valves
Close the main hot and cold isolation valves under the heater. This cuts the heater off from the house so the solution only goes through the heater.
- 5
Gloves and glasses
Wear gloves and eye protection when you handle the descaling solution and the hoses.
Tools you'll need
Grab these first
Tool and part links are affiliate links. We may earn a commission at no extra cost to you, and it never changes what we tell you to check first. How this works
- Tankless flush kitSubmersible pump, two hoses, bucketA small pump in a bucket pushes the solution through the heater, and two hoses connect it to the service ports.Typically $80–$160Shop this tool
- Descaling solutionFood-grade white vinegar or tankless descalerUndiluted food-grade white vinegar or a descaler made for tankless heaters, whichever your manual calls for. Plan on about 4 gallons.Typically $10–$50Shop this tool
- Bucket5 galCatches the water that comes out when you open the service ports. A spare bucket helps for the rinse.Typically $4–$10Shop this tool
- Adjustable wrench8–10 in.OptionalSnugs the hose fittings on the service ports if hand tight is not enough.Typically $10–$25Shop this tool
- Nitrile glovesKeeps the descaling solution off your hands.Typically $8–$15Shop this tool
- Safety glassesVinegar or descaler can spray when you connect or pull a hose.Typically $5–$15Shop this tool
- Stiff nylon brushOptionalScrubs the inlet filter screen once the flush is done. An old toothbrush works too.Typically $5–$12Shop this tool
Step by step
How to flush and descale a tankless water heater
- 1
Turn off the power
Gas unit: unplug its power cord, or turn off its breaker if it is wired in. Pressing the power button on the controller does not count.
Electric unit: turn off every breaker that feeds it at the main panel. Many whole-house electric tankless heaters use two or more double breakers.
- 2
Gas units: close the gas shutoff
Find the quarter-turn shutoff on the gas line under the heater. Turn the handle so it sits across the pipe.
Electric unit? Skip this step.
Careful. Closing the shutoff is the only thing you do to the gas line. Never loosen a gas fitting or open the heater's gas parts.
- 3
Close the isolation valves
Under the heater you will find two isolation valves: one on the cold line in, one on the hot line out. Each has a main handle and a small service port with a cap and its own little handle.
Close both main handles. The heater is now cut off from the house plumbing.
Tip. No service ports on your valves? The heater was installed without an isolation valve kit. A plumber can add one, and it makes every future flush easy.
- 4
Relieve the pressure and open the service ports
Set a bucket under the valves. Take the cap off each service port slowly, so any pressure left inside bleeds off. Some water will run out.
Careful. If the unit ran recently, that water can be hot. Go slowly and keep your face clear of the ports.
- 5
Hook up the pump and hoses
Connect one hose from the pump's outlet to the cold side service port. Connect the second hose to the hot side service port and lay its free end in the bucket. Most ports take a standard 3/4 in. hose thread.
Pour the descaling solution into the bucket and set the pump in it. Plan on about 4 gallons. Use what your manual names: many call for undiluted food-grade white vinegar, others a descaler made for tankless heaters.
Tip. Some makers want the inlet filter screen left in place during the flush and cleaned right after. Check your manual before you pull it.
Buy the part
Descaling flush
Opens Amazon in a new tab. Where’s my model number?
What to look for
- A kit with a small submersible pump, two hoses and a bucket. The hoses need to fit your service ports, which are usually 3/4 in. hose thread.
- The solution your manual names: undiluted food-grade white vinegar, or a descaler made for tankless water heaters.
- About 4 gallons of solution for one flush.
Flush kits are not tied to any brand of heater. Any pump and hose set that fits the service ports does the job, and you keep it for every flush after.
- 6
Open the service ports and run the pump
Open the small handles on both service ports. Plug in the pump. The solution should flow up through the heater and back into the bucket in a steady loop.
Let it circulate for as long as your manual says. Makers call for anything from 30 minutes to an hour or more, and some want a certain flow rate. Around 45 to 60 minutes is common.
Tip. Check the hose connections for drips in the first minute, while you can still tighten them easily.
- 7
Rinse with fresh water
Unplug the pump. Close the small handle on the cold side service port, leave the hot side hose running into the bucket or a drain, and slowly open the main cold isolation valve. Fresh water pushes the solution out of the heater.
Let it run until the solution is out, for as long as your manual says. Makers call for about 5 to 10 minutes. Empty the bucket as it fills. Then close the cold isolation valve again.
Careful. Close the cold service port before you open the main cold valve. Otherwise house water pressure pushes back out through that port and the pump hose.
- 8
Clean the inlet filter screen
With the water still off, unscrew the inlet filter screen at the heater's cold water inlet, rinse off any grit and scale, and screw it back in by hand. The inlet filter guide walks through it.
- 9
Close the service ports and cap them
Close the small handles on both service ports, take the hoses off and put the caps back on.
- 10
Open the isolation valves and purge the air
Open the main cold and hot isolation valves all the way. Check the caps and the inlet screen for drips.
Open a hot faucet in the house and let it run until the flow is steady and any trace of the solution is gone.
Careful. Electric unit: the breakers stay off until the water runs steady with no sputtering, usually 3 to 5 minutes. Powering an element with air in its chamber can burn it out.
- 11
Gas units: open the gas shutoff
Turn the gas shutoff handle back in line with the pipe. Electric unit? Skip this step.
- 12
Turn the power back on
Plug the heater back in or turn its breakers on. Open a hot tap and check that the heater fires and the water gets hot.
Write the date somewhere on or near the heater so you know when the next flush is due.
Buy the part
Get the right replacement
Buy the part
Descaling flush
Opens Amazon in a new tab. Where’s my model number?
What to look for
- A kit with a small submersible pump, two hoses and a bucket. The hoses need to fit your service ports, which are usually 3/4 in. hose thread.
- The solution your manual names: undiluted food-grade white vinegar, or a descaler made for tankless water heaters.
- About 4 gallons of solution for one flush.
Flush kits are not tied to any brand of heater. Any pump and hose set that fits the service ports does the job, and you keep it for every flush after.
Know your limits
When to call a pro
Stop and call a pro if
- Your heater has no isolation valves with service ports. A plumber can add a valve kit so it can be flushed.
- Your manual or warranty says a licensed pro must do the descaling. Some makers do.
- The scale code or the weak hot water comes back soon after a flush. The scale may be heavy, or something else is wrong.
- A service port or isolation valve leaks, or a handle will not turn.
- You smell gas at any point. Leave the house and call the gas utility from outside.
FAQ
Descaling flush questions
How often should I flush a tankless water heater?
Most makers call for about once a year. With hard water, every six months is common, and electric tankless makers give a six to twelve month range depending on hardness. Your manual has the number for your model.
Some heaters track scale and tell you when it is time with a code or a message.
Vinegar or a descaler?
Use what your manual names. Many call for plain undiluted food-grade white vinegar, which is cheap and safe. Others allow a descaler made for tankless heaters, which can work faster. Do not use anything your manual does not list.
Do electric tankless heaters need descaling too?
Yes. The heating chambers scale up the same way. Makers suggest flushing every six months to a year depending on water hardness, and keeping the temperature setting moderate helps slow it down.
Will a water softener mean I never have to flush?
A whole-house softener removes most of the calcium and magnesium that form scale, so the heater scales up far more slowly. Keep checking it on the schedule in your manual anyway.
Can I flush it myself without hurting the warranty?
Usually, and skipping it can hurt you more: at least one maker does not cover damage from lime build-up. But some makers write their descaling procedure for service pros only, so read your warranty and manual first.
Related
Keep going
- SymptomTankless water heater scale buildupTankless gas and electric water heaters only. Temperature swings, weaker hot water, rising bills or a scale or overheat code in a hard water area. Scale in the heat exchanger is the usual reason, and a flush clears it.Open guide
- SymptomTankless water heater showing an error codeTankless gas and electric water heaters only. The display shows a code and the hot water stops or comes and goes. Note the code, look it up in your manual, then check gas, water valves, the inlet filter and scale.Open guide
- SymptomTankless water heater: no hot water at low flowTankless gas and electric water heaters only. Hot water works at full flow but not at a trickle or at one low-flow fixture. The flow is below the heater's minimum activation flow, or something is cutting flow.Open guide
- Water heater partInlet filter screenTankless gas and electric water heaters only. A small mesh screen at the cold water inlet catches grit before it reaches the flow sensor and heat exchanger. When it clogs, hot water flow drops and the heater can stop firing.Open guide
- Water heater partFlow sensorTankless gas and electric water heaters only. The flow sensor is a little turbine on the cold inlet that tells the control board water is moving. When it sticks or fails, the heater never fires, or cuts out mid-shower.Open guide
- Water heater partTankless heating elementTankless electric water heaters only. The unit heats water as it flows through heating chambers, each with its own element. A burned-out element tests open on a meter and swaps out with the power and water off.Open guide
Get the next fix before it breaks
A short email when the seasons turn: filters to change, detector batteries to check, and new repair guides. No spam, unsubscribe any time.
We send it with Kit. Privacy