No hot water at low flow from your tankless heater
Full blast runs hot, but a gentle trickle stays cold. Your heater is probably fine. It just is not seeing enough water to turn on.
Check these first
Five-minute checks, no tools
Open the tap further
Turn the faucet or shower further open, and fully to the hot side. If it heats now, the flow was below the heater's minimum. Check that figure in your manual.
Clean the aerator or showerhead
If only one fixture stays cold, unscrew its aerator or showerhead and rinse out the grit. A blocked one cuts flow at that fixture alone.
Isolation valves fully open
The hot and cold valves under the heater should be fully open for normal use. One left partly closed after a flush cuts the flow to every tap.
Inlet filter clean
Flow weak everywhere? The small screen where cold water enters the heater may be packed with sediment. See the [inlet filter guide](/water-heater/tankless-inlet-filter).
Crossover or recirculation
A worn single-handle valve or a recirculation crossover valve can let cold water into the hot line, so less water flows through the heater. See [cold water sandwich](/water-heater/symptoms/tankless-cold-water-sandwich) for a simple test.
Likely causes
Ranked by how often they are the problem
- 1DIY fix
Flow below the minimum activation flow
Hot at full flow, cold at a trickle or at one very low-flow fixture. Nothing is broken. Open the tap further, use a fixture that flows a little more, or ask a plumber about a heater with a lower minimum.
- 2DIY fix
Clogged aerator or showerhead
One fixture is cold while the others heat fine. Grit in its aerator or showerhead has cut its flow below what the heater needs.
- 3DIY fix
Clogged inlet filter
Every hot tap is weaker than it used to be. A sediment-packed inlet screen cuts flow through the whole heater. Rinsing it with the water off is quick.
Fix the inlet filter15–30 min$5–$30 - 4DIY fix
Isolation valve partly closed
Flow dropped right after a flush or service. One of the valves under the heater was not opened all the way. Open both fully.
- 5DIY fix
Cold water crossing into the hot line
Water keeps running from a hot tap during the crossover test, with the heater's cold valve closed. Cold water is mixing in through a worn single-handle valve or a recirculation crossover valve, so less water goes through the heater.
- 6DIY fix
Scale in the heat exchanger
Hard water and a heater that has not been flushed in a long while. Minerals build up inside the heat exchanger and hamper heat transfer, and the heater struggles to keep up. A descaling flush clears it.
Fix the descaling1.5 hr–2.5 hr$10–$50 - 7DIY fix
Dirty or failing flow sensor
Flow is good, the filter is clean and the valves are open, but the heater still will not fire at a modest flow. Debris in the sensor's turbine, or a failing sensor, can keep it from seeing the water.
Fix the flow sensor45 min–1.5 hr$25–$65
What's happening
What your water heater is doing
A tankless heater has no tank of hot water waiting. A flow sensor inside watches the water coming in, and the heater only fires once the flow reaches a set minimum, called the minimum activation flow. Below that, water passes through cold.
That minimum depends on the model. Many units need around half a gallon per minute, and some newer ones start lower. Your manual or the spec sheet lists the figure for your heater.
Very low-flow faucets and showerheads, a tap opened only a little, or a single-handle faucet set mostly to cold can all sit below that line. The heater may also start, then cut out when the flow drops, which feels like hot then cold.
If low flow is new, or every tap seems weaker than it used to, something may be restricting the water: a clogged inlet filter, a partly closed isolation valve, scale inside the heat exchanger, or a dirty flow sensor.
Know your limits
When to call a pro
Stop and call a pro if
- Your low-flow fixtures sit below your heater's minimum activation flow and you want a fix, like a heater with a lower minimum or a small buffer tank.
- The crossover test shows cold water getting into the hot line and you cannot find the fixture or valve doing it.
- The heater will not fire at good flow with a clean filter and open valves.
- You are not comfortable working on the heater's water connections.
FAQ
Common questions
What is the minimum flow rate for a tankless water heater?
It depends on the model. Many units need about half a gallon per minute to fire, and some newer ones start lower. Check your manual or spec sheet for the activation flow of your heater.
Why does my bathroom faucet run cold but the shower is hot?
Bathroom faucets often flow very little, especially when opened only part way. That can be below the heater's minimum. Open it further and clean its aerator. If it heats at full flow, the heater is working as designed.
Can low-flow fixtures work with a tankless heater?
Usually, as long as the fixture's flow is above the heater's activation flow. Compare the two figures before you buy either one. Some heaters are built with a lower minimum for this reason.
Related
Keep going
- SymptomTankless water heater goes hot, cold, then hot againTankless gas and electric water heaters only. The shower runs hot, turns cold for a few seconds, then hot again, often after you shut the water off and turn it back on. Check flow, the fixture and the filter.Open guide
- SymptomTankless water heater scale buildupTankless gas and electric water heaters only. Temperature swings, weaker hot water, rising bills or a scale or overheat code in a hard water area. Scale in the heat exchanger is the usual reason, and a flush clears it.Open guide
- SymptomTankless water heater showing an error codeTankless gas and electric water heaters only. The display shows a code and the hot water stops or comes and goes. Note the code, look it up in your manual, then check gas, water valves, the inlet filter and scale.Open guide
- SymptomWater heater not making enough hot waterThe shower starts hot and goes cold too soon, or the water is never more than warm. Check the temperature setting first, then the lower element and thermostat on electric units, the dip tube and sediment.Open guide
- Water heater partFlow sensorTankless gas and electric water heaters only. The flow sensor is a little turbine on the cold inlet that tells the control board water is moving. When it sticks or fails, the heater never fires, or cuts out mid-shower.Open guide
- Water heater partInlet filter screenTankless gas and electric water heaters only. A small mesh screen at the cold water inlet catches grit before it reaches the flow sensor and heat exchanger. When it clogs, hot water flow drops and the heater can stop firing.Open guide
- Water heater partDescaling flushTankless gas and electric water heaters only. Hard water leaves scale inside the heat exchanger or heating chambers. A yearly flush with a pump and descaling solution through the isolation valves' service ports dissolves it.Open guide